ZWNS Vacuum Hot Water Boiler
Negotiable
China
No. 21, Chuangye West Road, Xinbei District, Changzhou City, Jiangsu Province
8618015810256
Online Contact
Favorite
Product Introduction
  • NOx Emission Value: ≤30mg/m³ with ultra-low NOx burner.
  • Thermal Efficiency: 98-104%, condensing boiler. The lower the return water temperature, the higher the efficiency.

Product Features and Advantages

  • Negative Pressure Operation, No Inspection Required:
    It does not fall under the "Pressure Vessel Safety Regulations," exempting it from inspection, saving costs.

  • Vacuum Environment Prevents Scaling:
    The inside of the boiler maintains a high vacuum and is oxygen-free, using softened heat transfer water, which does not need to be replaced during the boiler's service life, and prevents scaling.

  • Efficient Insulation with Minimal Heat Loss:
    Uses new lightweight insulation materials that reduce heat loss, providing excellent thermal performance.

  • Comprehensive Protection for Peace of Mind:
    Equipped with over-temperature, overpressure, and leak protection systems to ensure stable operation and safety.

  • Fully Assembled for Quick Installation:
    The compact, integrated design is fully assembled and ready for installation, making the process quick and reducing construction time.

  • High-Efficiency Combustion with Low NOx Emissions:
    Equipped with a well-known brand burner for complete combustion, high thermal efficiency, and low fuel consumption, achieving low NOx emissions.

  • Multi-Purpose Design with Multiple Coil Technology:
    Can be configured with different heat exchangers for heating and hot water applications, significantly simplifying the system and reducing equipment costs, saving investment.

  • Condensing Heat Exchange for Fuel Savings:
    A condenser can be installed at the flue outlet to absorb the latent heat of the flue gases, significantly enhancing fuel savings, with thermal efficiency exceeding 100%.

  • Corrosion-Resistant Special Steel Condenser:
    To prevent acid corrosion from flue gas condensation, ND steel and other special steels are used for the finned tubes, improving both corrosion resistance and heat transfer efficiency.

  • Intelligent Control with Multi-Unit Group Control:
    Features a colorful touchscreen PLC control system for easy operation, automatic fault diagnosis, and fully automatic operation.

This boiler is designed for high efficiency, environmental friendliness, and ease of use, making it a versatile and reliable option for various heating and hot water needs.

Product Parameter
 (Model)  (Rated Power) MW  (Inlet/Outlet Water Temperature) ℃ (AC Heating Water Flow) m³/h  (AC Heating Pressure Loss) kPa  (Radiator Heating Inlet/Outlet Temp) ℃  (Radiator Heating Water Flow) m³/h  (Radiator Heating Pressure Loss) kPa  (Domestic Hot Water Inlet/Outlet Temp) ℃  (Domestic Hot Water Flow) m³/h  (Domestic Hot Water Pressure Loss) kPa  (Thermal Efficiency) %  (Applicable Fuel) (Natural Gas Consumption) Nm³/h (LPG Consumption) Nm³/h (Light Diesel Consumption) kg/h (Power Consumption) kW  (Voltage) V  (Weight) T  (Water Capacity) m³  (NOx Emission Value)
ZWNS 0.35 0.35 50/60 30 7 60/80 15 7 40/60 15 7 93%-94% natural gas/liquefied gas/light diesel oil 38 13.4 31.5 1.5 220、380/50Hz 2.15 0.8 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 0.7 0.7 50/60 60 12 60/80 30 12 40/60 30 12 93%-94% natural gas/liquefied gas/light diesel oil 75.9 26.9 63 2.2 220、380/50Hz 2.77 1.5 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 0.93 0.93 50/60 80 12 60/80 40 12 40/60 40 12 93%-94% natural gas/liquefied gas/light diesel oil 100.8 35.8 84 2.2 220、380/50Hz 4.08 2 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 1.05 1.05 50/60 90 13 60/80 45 13 40/60 45 13 93%-94% natural gas/liquefied gas/light diesel oil 115.4 40.9 92.8 3.15 220、380/50Hz 4.38 2 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 1.4 1.4 50/60 120 13 60/80 60 13 40/60 60 13 93%-94% natural gas/liquefied gas/light diesel oil 151.8 53.8 126 5.5 220、380/50Hz 4.38 2.2 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 1.75 1.75 50/60 150 14 60/80 75 14 40/60 75 14 93%-94% natural gas/liquefied gas/light diesel oil 189.8 67.2 157.5 5.5 220、380/50Hz 6.05 3.7 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 2.1 2.1 50/60 180 14 60/80 90 14 40/60 90 14 93%-94% natural gas/liquefied gas/light diesel oil 227.7 80.6 189 9.2 220、380/50Hz 7.05 3.8 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 2.34 2.34 50/60 200 14 60/80 100 14 40/60 100 14 93%-94% natural gas/liquefied gas/light diesel oil 254 89.5 210.6 9.2 220、380/50Hz 7.52 3.8 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 2.8 2.8 50/60 210 15 60/80 120 15 40/60 120 15 93%-94% natural gas/liquefied gas/light diesel oil 303.6 107.5 252 9.2 220、380/50Hz 9.65 6.5 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 3.5 3.5 50/60 300 16 60/80 150 16 40/60 150 16 93%-94% natural gas/liquefied gas/light diesel oil 379.5 134.4 315.1 15 220、380/50Hz 11.35 6.3 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 4.2 4.2 50/60 360 17 60/80 180 17 40/60 180 17 93%-94% natural gas/liquefied gas/light diesel oil 455.4 161.3 378 15 220、380/50Hz 14.55 8 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 5.6 5.6 50/60 480 18 60/80 240 17 40/60 240 17 93%-94% natural gas/liquefied gas/light diesel oil 607.3 215.1 504.1 22 220、380/50Hz 17.55 14 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 7 7 50/60 600 20 60/80 300 17 40/60 300 17 93%-94% natural gas/liquefied gas/light diesel oil 759 268.9 630 25 220、380/50Hz 22.55 15.4 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³