C3 and E3 Series Digital Multifunctional Electrical Measuring Instruments
Negotiable
China
No. 790, Pengfeng Road, Songjiang Science and Technology Park, Shanghai
+8621-57858383
Online Contact
Favorite
Product Introduction

This product features an attractive design with a panel that includes five buttons for convenient operation. The instrument is equipped with a standard RS485 MODBUS communication interface. The KLY-D96-C3 and KLY-D96-E3 series come with built-in, non-pluggable expandable modules, allowing for the selection of up to two sets of transmitter modules, two sets of relay modules, or a combination of two sets of transmitter modules and two sets of relay modules. It is manufactured in accordance with the GB/T22264-2008 standard.

Product Specifications

Technical Symbols

Product Model

Measurement range

Measurement type

Auxiliary power supply

Accuracy class

Overall dimension

Display

Extended functionality

C3, E3 series Digital Functional electrical measuring instruments

KLY-D72-M-C3

KLY-D72-M-E3

Voltage:20 ~ 400VAC

(L-N phase/medium)

35 to 690VAC

  1. L phase/phase)

Current:

The maximum value of 99999A is measured at one time

Secondary measurement rating:1A, 5A

Frequency: 45~65Hz

Current

Voltage

Frequency

Active power

Reactive power

Apparent Power

Power factor

Voltage unbalance degree

Current unbalance degree

Temperature

Electrical energy measurement

C:DC24V

D:AC85V~265V

DC85V ~ 265V

Current: 0.2

Voltage: 0.2

Frequency: 0.1

Active power: 0.5

Reactive power: 1.0

Apparent Power: 1.0

Power factor: 0.5

Active electrical degree: 0.5

Reactive electrical degree: 2.0

Apparent electrical degree: 1.0

72(H)×72(W)×108(D)

Opening size: 68(H) x 68(W)

4 digit digital tube display

Or

4-digit segment LCD display

485 communication standard

KLY-D96-M-C3

KLY-D96-M-E3

96(H)×96(W)×92.6(D)

Opening size: 92(H) x 92(W)

Standard 485 communication,

With 2 analog output modules,

With 2-way relay output module,

With 2 analog output modules

+2 relay output module

KLY-D72-3A-C3

KLY-D72-3A-E3

Current:

maximum primary side 99999A

Secondary side Rating:

1A, 5A

Current

C:DC24V

D:AC85V~265

DC85V ~ 265V

Current: 0.2

72(H)×72(W)×108.4(D)

Opening size: 68(H) x 68(W)

4 digit digital tube display

Or

4-digit segment LCD display

485 communication standard

KLY-D72-3V-C3

KLY-D72-3V-E3

Voltage:

20 ~ 400VAC

  1. N phase/medium)

35 to 690VAC

(L-L phase/phase)

Voltage

Voltage: 0.2

KLY-D72-AVF-C3

KLY-D72-AVF-E3

Current:

Primary side maximum 99999A

Secondary side Rating:

1A, 5A

Voltage:

20 ~ 400VAC

  1. N phase/medium)

35 to 690VAC

  1. L phase/phase)

Frequency.45~65Hz

Current

Voltage

Frequency

Current: 0.2

Voltage: 0.2

Frequency: 0.1

KLY-D96-3A-C3

KLY-D96-3A-E3

Current:

maximum primary side 99999A

Secondary side Rating:

1A, 5A

Current

C:DC24V

D:AC85V~265V

DC85V ~ 265V

Current: 0.2

96(H)×96(W)×92.6(D)

Opening size: 92(H) x 92(W)

4 digit digital tube display

Or

4-digit segment LCD display

Standard 485 communication,

With 2 analog output modules,

With 2-way relay output module,

With 2 analog output modules

+2 relay output module

KLY-D96-3V-C3

KLY-D96-3V-E3

Voltage:

20 ~ 400VAC

  1. N phase/medium)

35 to 690VAC

(L-L phase/phase)

Voltage

Voltage: 0.2

KLY-D96-AVF-C3

KLY-D96-AVF-E3

Current:

maximum primary side 99999A

Secondary side Rating:

1A, 5A

Voltage:

20 ~ 400VAC

(L-N phase/medium)

35 to 690VAC

  1. L phase/phase)

Frequency: 45~65Hz

Current

Voltage

Frequency

Current: 0.2

Voltage: 0.2

Frequency: 0.1