DC Input
Input Voltage: Rated 600Vdc, Operating Range 250-900Vdc
Input Overvoltage Protection: 905±5Vdc
Input Undervoltage Protection: 245±5Vdc
DC Output
Rated Output Power: 40kW
Output Voltage Range: 50-1000Vdc
Output Current Range: 0-134A
Output Constant Power Range: 300-1000Vdc at 40kW
Peak Efficiency: ≥98.5%
Soft Start Time: ≤3S
Short Circuit Protection: Shutdown and lock after short circuit, recoverable only after power restart
Voltage Regulation Accuracy: ≤±0.5%
Current Regulation Accuracy: ≤±1%
Current Sharing Imbalance: ≤±5%
Operating Environment
Operating Temperature: -40℃~75℃
Relative Humidity: 5%RH-95%RH, no condensation
Altitude: ≤2000m (derating required above 2000m)
Product Characteristics
Cooling Method: Liquid cooling
Communication Bus Protocol: CAN
Standby Power Consumption: ≤10W
Address Setting: Digital screen display, key operation
Module Dimensions (excluding handles): 460mm×300mm×120mm
Weight: ≤28KG (including liquid)
MTBF: 500,000 hours