2000kW Fixed Fuel Cell Power Station

Negotiable
China
No. 1555 Jingyuan Road, Jiading District, Shanghai City 201800
Online Contact
Favorite
Product Introduction

This series of power stations is entirely designed, developed, and produced by REFIRE through its proprietary full-process capabilities. With a rated power of 2000kW and a peak power reaching 2200kW, its power generation efficiency and output voltage platform can be customized according to specific scenarios, supporting combined heat and power (CHP) generation. The modular architecture supports the parallel operation of multiple power stations. It adopts a skid-mounted structure and containerized layout for rapid deployment and flexible transportation. Equipped with a comprehensive safety system, it supports black start, remote monitoring, and unattended operation. Supporting seamless switching between grid-connected and off-grid dual modes, it is widely adaptable to the full spectrum of energy needs, including hydrogen energy storage for peak shaving, industrial energy hubs, data center backup power, commercial complexes, smart communities, and off-grid isolated islands, redefining the application boundaries of distributed energy.

Product Features

  • Ultra-Environmentally Friendly: Zero emissions, low noise

  • High Safety: Comprehensive systematic safety design, including intrinsic safety designs for fire prevention, waterproofing, electric shock prevention, electromagnetic compatibility, explosion protection, hydrogen safety, structural safety, functional safety, and full life-cycle safety management regulations

  • High Returns: Customizable power generation efficiency, capable of achieving combined heat/power/water supply

  • High Reliability: Three-tier verification system, power redundancy design, modular isolation design, uninterruptible power supply

  • Long Lifespan: Self-developed fuel cell system, supports 7*24h operation, lifespan exceeding 40,000 hours

  • Intelligent: Flexible switching between multiple operation modes, automatic warning and protection, remote monitoring and unattended operation

  • High Integration: Skid-mounted design, rapid deployment, flexible transportation

  • High Compatibility: Capable of parallel operation with multiple power stations, and parallel operation with traditional fuel/gas generator sets or electrochemical energy storage

  • Fast Response: Second-level dynamic response, seamless switching between grid-connected and off-grid modes

  • High Adaptability: Low-temperature lossless rapid start at -30°C, high-altitude self-adaptation

Product Parameters

Mechanical Parameters

Integration Form

Split Type: Container A / Container B not integrated

(Container A: Power Generation Container, Container B: Electrical Container)

Installation Method

Containerized

Overall Dimensions (Power Generation Container)

≤12500(L)×3000(W)×3000(H) mm

Overall Dimensions (Electrical Container)

≤6000(L)×2500(W)×2600(H) mm

Overall Dimensions (Water Cooling Unit)

≤12000(L)×2600(W)×3800(H) mm

Weight (Power Generation Container)

≤32000 kg

Weight (Electrical Container)

≤12000 kg

Weight (Water Cooling Unit)

≤18000 kg

DC Side Parameters

Maximum DC Output Power

2200 kW (Backup Version) / 2860 kW (Primary Version)

(Primary Version: Long-duration power generation, Backup Version: Short-duration power generation, Power adjustable)

DC Bus Voltage Range

450~750 VDC / 1000~1400 VDC

AC Side Parameters

Rated Output Power

2000 kW

Maximum Output Power

2200 kW

Voltage System

Three-phase three-wire / Three-phase four-wire

Rated Output Voltage

AC 10 kV (Customizable)

Power Generation Efficiency at Rated Power Point

13.0~16.0 kWh/kg (Customizable)

Operating Mode

Grid-connected / Off-grid

Cooling Parameters

Cooling Solution

Water Cooling

Combined Heat and Power (CHP)

Configurable

CHP Hot Water Temperature

≤75℃

CHP Overall Efficiency

≥80%

External Hydrogen Supply Parameters

Hydrogen Supply Pressure Range

≥1.5 Mpag

Hydrogen Purity Requirement

≥99.97%, GB / T 37244

Unit Parameters

Continuous Ramp-up/Ramp-down Rate

(Fuel Cell System Response Only)

240 / 240 kW/s

Instantaneous Ramp-up/Ramp-down Rate

(Supported by Power Battery)

1000 / 1000 kW/s

Normal Temperature Startup/Shutdown Time

(Startup~Rated, Rated~Shutdown, ≥10℃)

≤60 / ≤60 s

Low Temperature Startup/Shutdown Time

(Startup~Rated, Rated~Shutdown, ≥30℃)

≤5 / ≤10 min

Ambient Temperature Range

-30 ~ 45℃

Ambient Altitude Range

≤3000 m

Design Life

≥40000 h

Black Start Capability

Supported

Communication Interface

Ethernet / RS485 / CAN2.0B

Design Standard

GB / T 27748