Off-Grid Fuel Cell Supercharging Station (50kW Configuration)

Negotiable
China
No. 1555 Jingyuan Road, Jiading District, Shanghai City 201800
Online Contact
Favorite
Product Introduction

The off-grid ultra-fast charging station utilizes 3 sets of REFIRE 50kW fuel cell stacks to achieve fuel cell system conversion. Independently developed and produced by Remold's core technology team, it requires no infrastructure construction or capacity expansion. Occupying only the space of a single parking space, it delivers an ultra-fast charging experience with a maximum charging power of 480kW, ready for immediate use. Multiple hydrogen storage modes are available, including pipeline hydrogen supply and solid-state hydrogen storage. It operates fully automatically with real-time safety monitoring.

Product Features

  • Rapid deployment speed: No on-site infrastructure construction required, operational upon installation.
  • Low process cost: No approval or construction permits needed, flexible relocation.
  • Strong scalability: Rapid iteration, no secondary modifications required; charging capacity can be quickly expanded based on market demand.
  • Low investment cost: No grid capacity expansion or site construction required, self-contained system.
  • Fast charging speed: Maximum single-gun charging power of 480kW, sustained power of 120kW, enabling faster charging turnover.
  • Small footprint: The power generation unit occupies only the space of one parking space.
  • Safe and intelligent: Real-time hydrogen safety monitoring, hydrogen level monitoring, no manual supervision required, intelligent, safe, and efficient.
Product Parameters

Mechanical Parameters

Overall Dimensions 5500×2200×2480 mm
Footprint 12.1 m²
Weight ≤10 t (excluding solid-state hydrogen storage module)

Charging Parameters

Max. Charging Power per Gun 480 kW
Sustained Charging Power of Unit 120 kW
Duration of Max. Charging Power 12 min
Output Voltage Range 200 - 1000 VDC
Charging Interface/Protocol National Standard (CCS1 / CCS2 optional)
Charging Start Time 15 s
Power Ramp-up Time 60 s
Number of Charging Terminals & Guns 4/4

External Hydrogen Supply Parameters

Hydrogen Supply Pressure Range 1.0 ± 0.15 MPa
Hydrogen Quality Requirement ≥99.97%, GB/T 37244
Hydrogen Supply Interface Specification SWAGELOK 1/2 inch

Solid-State Hydrogen Storage Parameters

Number of Modules 1-3 (customizable)
Theoretical/Available Hydrogen Storage per Module 15/12 kg
Power Generation per Hydrogen Storage Module 168 kWh
Module Replacement Time 10 - 15 min

Overall Unit Parameters

Hydrogen Supply Method Solid-State Hydrogen Storage Module / External Gaseous Hydrogen Supply
Average Power Generation Efficiency ≥14.0 kWh/kg
Protection Rating IP54
Operating Noise ≤85 dB@40 °C, ≤75 dB@25 °C
Operating Ambient Temperature -20 - 40 °C