1500kW Fixed Fuel Cell Power Station

Negotiable
China
No. 1555 Jingyuan Road, Jiading District, Shanghai City 201800
Online Contact
Favorite
Product Introduction

This series of power stations was independently designed, developed, and produced by REFIRE through the entire process; with a rated power of 1500kW and a peak power reaching 1650kW, the power generation efficiency and output voltage platform can be customized according to the scenario, supporting combined heat and power generation; the modular architecture supports parallel operation of multiple power stations; it adopts a skid-mounted structure and containerized layout for rapid deployment and flexible transportation; equipped with a comprehensive safety system, supporting black start, remote monitoring, and unmanned operation. It supports seamless switching between grid-connected/off-grid dual modes, widely adapting to full-scenario energy demands such as hydrogen energy storage for peak shaving, industrial energy hubs, data center backup power, commercial complexes, smart communities, and off-grid isolated islands, redefining the application boundaries of distributed energy.

Product Features

  • Ultra-Environmental: Zero emissions, low noise

  • High Safety: Comprehensive systematic safety design, including inherent safety designs and full lifecycle safety management regulations for fire prevention, water resistance, electric shock protection, electromagnetic compatibility, explosion protection, hydrogen safety, structural safety, functional safety, etc.

  • High Return: Customizable power generation efficiency, capable of achieving combined heat/power/water supply

  • High Reliability: Three-level verification system, power redundancy design, modular isolation design, uninterruptible power supply

  • Long Lifespan: Self-developed fuel cell system, supports 7*24h operation, lifespan exceeding 40,000 hours

  • Intelligent: Flexible switching between multiple operation modes, automatic warning and protection, remote monitoring and unmanned operation

  • High Integration: Skid-mounted design, rapid deployment, flexible transportation

  • High Compatibility: Capable of parallel operation of multiple power stations, can operate in parallel with traditional fuel/gas generator sets or electrochemical energy storage

  • Fast Response: Second-level dynamic response, seamless grid connection/disconnection switching

  • High Adaptability: -30°C low-temperature lossless rapid start, high-altitude self-adaptation

Product Parameters

Mechanical Parameters

Integration Form

Integrated: A Container / B Container Integration

(A Container: Power Generation Container, B Container: Electrical Container)

Installation Method

Containerized

Overall Dimensions (Power Station Container)

≤12500(L)×3000(W)×3000(H) mm

Overall Dimensions (Water-cooled Unit)

≤6000(L)×2600(W)×3800(H) mm

Weight (Power Station Container)

≤35000 kg

Weight (Water-cooled Unit)

≤9000 kg

DC Side Parameters

Maximum DC Output Power

1760 kW (Standby Version) / 2160 kW (Primary Version)

(Primary Version: Long-duration power generation, Standby Version: Short-duration power generation, Power adjustable)

DC Bus Voltage Range

450~750 VDC / 1000~1400 VDC

AC Side Parameters

Rated Output Power

1500 kW

Maximum Output Power

1650 kW

Voltage System

Three-phase three-wire / Three-phase four-wire

Rated Output Voltage

AC 10 kV / 380 V (Customizable)

Power Generation Efficiency at Rated Power

13.0~16.0 kWh/kg (Customizable)

Operating Mode

Grid-connected / Off-grid

Cooling Parameters

Cooling Solution

Air-cooled / Water-cooled

Combined Heat and Power (CHP)

Configurable

CHP Heat Temperature

≤75°C

Overall CHP Efficiency

≥80%

External Hydrogen Supply Parameters

Hydrogen Supply Pressure Range

≥1.5 MPa

Hydrogen Supply Quality Requirement

≥99.97%, GB/T 37244

Overall Unit Parameters

Continuous Ramp-up/Ramp-down Rate

(Fuel Cell System Response Only)

320 / 320 kW/s

Instantaneous Ramp-up/Ramp-down Rate

(Supported by Power Battery)

1000 / 1000 kW/s

Normal Temperature Startup/Shutdown Time

(Startup~Rated, Rated~Shutdown, ≥10℃)

≤60 / ≤60 s

Low Temperature Startup/Shutdown Time

(Startup~Rated, Rated~Shutdown, ≥-30℃)

≤5 / ≤10 min

Ambient Temperature Range

-30 ~ 45°C

Ambient Altitude Range

≤3000 m

Design Life

≥40000 h

Black Start Capability

Supported

Communication Interface

Ethernet / RS485 / CAN2.0B

Design Standard

GB/T 27748