Performance
|
Parameter
|
|
Accuracy Class
|
Class 2
|
|
Nominal Diameter
|
DN15-DN25
|
|
Turndown Ratio R
|
R160/R250/R400 (ordinary type)
|
|
Maximum Allowable Working Pressure
|
1.6MPa
|
|
Working Environment
|
-25℃~55℃, <100%RH (beyond this range, specify when ordering)
|
|
Temperature Class
|
T30, T50, default T30
|
|
Upstream Flow Field Sensitivity Class
|
U0
|
|
Downstream Flow Field Sensitivity Class
|
D0
|
|
Climate and Mechanical Environmental Conditions
|
O
|
|
Electromagnetic Compatibility Class
|
E2
|
|
Button
|
Photosensitive button
|
|
Display
|
LCD, 10-digit numbers + symbols
|
|
Display Content
|
Cumulative flow (m³), instantaneous flow (m³/h), water temperature (℃), cumulative effective running time, date (year/month/day) clock (hour/minute/second), software version/meter ID, screen detection
|
|
Display Resolution
|
Cumulative flow 0.0001m³, instantaneous flow 0.001m³/h, water temperature 0.01℃ (decimal places for cumulative flow and instantaneous flow can be customized)
|
|
Display Range
|
0m³~1999999.999m³
|
|
Data Communication
|
Optical Interface
|
Baud rate 2400bps, supports GB/T26831 (EN13757-3)
|
|
NB-IoT Network
|
Narrowband Internet of Things (NB-IoT network), data reporting period 1 day (beyond range, specify when ordering)
|
|
Data Communication
|
NB-IoT Network
|
1. Cumulative flow, cumulative running time and maximum flow stored monthly for the most recent 24 months.
|
|
2. The most recent 730 daily frozen cumulative volumes, cumulative running time and diagnostic codes.
|
|
3. Reporting history data for at least the most recent 1 month.
|
|
4. The most recent 60 reporting logs.
|
|
5. The most recent 100 alarm records.
|
|
6. Data can be saved for 100 years after power failure
|
|
Operating Power
|
Battery powered DC3.6V (continuous working life more than 10 years) Note 1: Weak signal, data retransmission, high alarm frequency will shorten battery life.
|
|
Pulse Output
|
Passive pulse output (external voltage requirement 3V < VDC < 40V, Imax: 25mA, pulse equivalent: 1L, 10L, 100L; pulse width ≤100ms. Non-standard output port, if needed, specify when ordering.
|
|
Protection Rating
|
IP68
|
|
Storage Temperature
|
-25℃~55℃
|
|
Meter Installation Position
|
Water supply pipe section without air bubble accumulation
|
|
Installation Method
|
Horizontal/Vertical
|