Features:

  • Has rectifying and stabilizing functions for the measured water field,
  • Not affected by water field turbulence or disturbance, making actual metering more accurate and reliable;
  • Has good anti-clogging function, measurement accuracy is not affected by dirt in the medium;
  • Has good ultrasonic conduction path;
  • Has good flow linearity;
  • Has good durability;
  • Sufficiently small pressure loss;
  • The pipe has sufficient pressure resistance and good sealing.

Product Parameters

Ordinary Type R400 Flow Parameter Table (Flow Unit: m³/h)

 

Minimum Flow Q1

Transitional Flow Q2

Common Flow Q3

Overload Flow Q4

Q3/Q1

Pressure Loss Class

DN15

0.00625

0.01

2.5

3.125

400

△p40

DN20

0.01

0.016

4

5

400

△p40

DN25

0.01575

0.0252

6.3

7.875

400

△p63

Ordinary Type R250 Flow Parameter Table (Flow Unit: m³/h)

 

Minimum Flow Q1

Transitional Flow Q2

Common Flow Q3

Overload Flow Q4

Q3/Q1

Pressure Loss Class

DN15

0.01

0.016

2.5

3.125

250

△p40

DN20

0.016

0.0256

4

5

250

△p40

DN25

0.0252

0.04032

6.3

7.875

250

△p63

Performance

Parameter

Accuracy Class

Class 2

Nominal Diameter

DN15-DN25

Turndown Ratio R

R160/R250/R400 (ordinary type)

Maximum Allowable Working Pressure

1.6MPa

Working Environment

-25℃~55℃, <100%RH (beyond this range, specify when ordering)

Temperature Class

T30, T50, default T30

Upstream Flow Field Sensitivity Class

U0

Downstream Flow Field Sensitivity Class

D0

Climate and Mechanical Environmental Conditions

O

Electromagnetic Compatibility Class

E2

Button

Photosensitive button

Display

LCD, 10-digit numbers + symbols

Display Content

Cumulative flow (m³), instantaneous flow (m³/h), water temperature (℃), cumulative effective running time, date (year/month/day) clock (hour/minute/second), software version/meter ID, screen detection

Display Resolution

Cumulative flow 0.0001m³, instantaneous flow 0.001m³/h, water temperature 0.01℃ (decimal places for cumulative flow and instantaneous flow can be customized)

Display Range

0m³~1999999.999m³

Data Communication

Optical Interface

Baud rate 2400bps, supports GB/T26831 (EN13757-3)

NB-IoT Network

Narrowband Internet of Things (NB-IoT network), data reporting period 1 day (beyond range, specify when ordering)

Data Communication

NB-IoT Network

1. Cumulative flow, cumulative running time and maximum flow stored monthly for the most recent 24 months.

2. The most recent 730 daily frozen cumulative volumes, cumulative running time and diagnostic codes.

3. Reporting history data for at least the most recent 1 month.

4. The most recent 60 reporting logs.

5. The most recent 100 alarm records.

6. Data can be saved for 100 years after power failure

Operating Power

Battery powered DC3.6V (continuous working life more than 10 years) Note 1: Weak signal, data retransmission, high alarm frequency will shorten battery life.

Pulse Output

Passive pulse output (external voltage requirement 3V < VDC < 40V, Imax: 25mA, pulse equivalent: 1L, 10L, 100L; pulse width ≤100ms. Non-standard output port, if needed, specify when ordering.

Protection Rating

IP68

Storage Temperature

-25℃~55℃

Meter Installation Position

Water supply pipe section without air bubble accumulation

Installation Method

Horizontal/Vertical