DF Series Nanofiltration Membrane Element

Negotiable
China
No. 23-2 BOW Building, West Ring Road, Life Science Park Road, Changping District, Beijing
+86 15506331377
Online Contact
Favorite
Product Introduction

DF (Dalton Filtration) series nanofiltration membrane elements are divided into DF30 ultra-low pressure and DF90 low pressure high desalination products. DF30 is used to remove total organic carbon (TOC) and trace organic pollutants, especially has a high removal rate for emerging pollutants (PCPs, EDCs, POPs), and has high permeability to dissolved inorganic salts, featuring high organic retention and low energy consumption. DF90 can remove hardness, heavy metals, sulfate, nitrate, chloride, fluoride, effectively remove trace organic pollutants such as PCPs and EDCs as well as microorganisms such as bacteria and viruses. It has the advantages of low operating pressure, high water production and high recovery rate. DF series nanofiltration membrane products are major landmark achievements of the National "Twelfth Five-Year Plan" Water Special Project, selected into the "National Catalog of Major Environmental Protection Technology Equipment Encouraged for Development" and "Zhongguancun National Independent Innovation Demonstration Zone First Set of Major Technical Equipment Demonstration Project", and have won scientific and technological honors such as "Beijing New Technology and New Product" as well as awards such as "National Science and Technology Progress Second Prize" and "Ministry of Education Science and Technology Progress First Prize".

Product Features

  • High Selective Separation
    Efficiently removes trace organic pollutants such as endocrine disruptors, antibiotics and disinfection by-products in water, moderately desalinates and retains minerals;
  • High System Recovery Rate
    The system recovery rate can reach up to 90%;
  • Low Operating Pressure
    Engineering operating pressure 0.3~0.5MPa, 30% lower than traditional nanofiltration membranes and reverse osmosis membranes;
  • Low Operating Cost
    High water production, less chemical consumption and low operating energy consumption.
Product Parameters

Specification Parameters

Membrane Element Model Average Water Production/GPD(m³/d) Stable Desalination Rate/% Effective Membrane Area/ft²(m²) Feed Spacer Width/mil
DF-8040-R30(400) 10000(37.9) 97.00 400(37) 31
DF-8040-R30G(400) 10000(37.9) 97.00 400(37) 31-LD
DF-4040-R30 1900(7.2) 97.00 85(8) 31
DF-4040-R90 1600(6.0) 99.00 85(8) 28
DF-8040-R90(400) 8000(30.3) 99.00 400(37) 28
DF-8040-R90(440) 8800(33.3) 99.00 440(41) 28
DF-8040-R90G(400) 8000(30.3) 99.00 400(37) 31-LD

Note: (1) Water production per single membrane element ±20%;
(2) Test conditions: pressure before membrane 70psi(0.48MPa), temperature 25℃, 2000ppm MgSO4 solution, recovery rate 15%, pH 7.5~8.0.

Maximum Feed Temperature (°C) 45 Allowed Free Chlorine Content (ppm) <0.1
Maximum Continuous Operating Temperature (when pH≥10) (°C) 35 Maximum Feed SDI15 5
Feed pH Range During Continuous Operation 3~10 Feed pH Range During Chemical Cleaning 2~12
Maximum Pressure Drop per Membrane Element 15psi(0.1MPa) Maximum Operating Pressure 365psi(2.5MPa)①③④⑤⑥
600psi(4.1MPa)②⑦