➤ Product Introduction
Instruments installed outdoors in low-latitude regions such as the equator and the Middle East can fail due to heavy rain and intense sun exposure; in high-latitude regions, outdoor cold conditions can freeze liquid crystal displays, impairing on-site readability. A patented universal outdoor instrument enclosure featuring rain protection, sun protection, freeze protection, as well as lighting, temperature control, and ventilation functions, provides a suitable operating environment for instruments and meters under harsh conditions.
➤ Main Performance Features
● Supports outdoor wall-mounted, pole-mounted (back-mounted), and column-mounted (base-mounted) installation methods;
● Features dust and rain protection (IP34) with natural convection and forced convection ventilation for heat dissipation;
● Equipped with thermal insulation and freeze protection (automatic heat tracing) functions, suitable for winter operation in high-latitude regions;
● Configured with a transparent observation window and internal lighting for convenient on-site inspection;
● Customizable size to accommodate different shapes or shared use by multiple instruments;
● Compatible with on-site mains power supply scenarios and backup battery power scenarios.
➤ Typical Applications
● On-site applications in wastewater treatment and environmental monitoring;
● Meets thermal insulation and freeze protection requirements for instruments and transmitters;
● Suitable for scenarios such as oil extraction, pipelines, and refining.
➤ Main Technical Parameters
| Enclosure Material | 201 Stainless Steel |
| Enclosure Dimensions | 410×300×220mm |
| Power Supply | AC (85~264)V; 50/60Hz |
| Built-in Power | DC 24V; 100W |
| Operating Environment | Temperature: (-20~50)℃; Humidity ≤85%RH (non-condensing) |
| Heater Power | 50W |
| Protection Rating | IP34 |
| Installation Method | Column (base) Pole (pipe) Wall-mounted |
| Pole Dimensions | Φ50mm × 1 meter |
| Pipe Clamp Mounting Dimensions | Φ50mm |
➤ Installation Accessories
| Instrument Name | Model | Unit | Order No. |
| Universal Data Acquisition Controller | MFC-8800 | Unit | 0301070204 |
| Universal Data Acquisition Controller | MFC-8600 | Unit | 0301070203 |
| Universal Data Acquisition Controller | MFC-7720 | Unit | 0301070202 |
| Universal Data Acquisition Controller | MFC-7700 | Unit | 0301070201 |
| Explosion-proof Data Acquisition Transmitter | MAE-8911 | Unit | 0301040301 |
| Explosion-proof Data Acquisition Transmitter | MAE-8912 | Unit | 0301040302 |
| Explosion-proof Data Acquisition Transmitter | MAE-8913 | Unit | 0301040303 |