Technical Specifications Table of Full Liquid-cooled Split DC Charging Reactor-Rectifier Cabinet |
|||
|
Serial Number |
Technical Indicator Name |
Technical Indicator Content |
|
|
1 |
Model |
RHAD480K-8YL RHAD600K-10YL |
RHAD720K-12YL |
|
2 |
Rated Power |
480kW 600kW |
720kW |
|
3 |
Output Loop |
8 Channels 10 Channels |
12 Channels |
|
4 |
Input Loop |
DUAL CHANNEL (DOUBLE SHELL) |
|
|
5 |
Overall Dimensions (W × D × H) |
1950 × 860 × 1980mm |
|
|
6 |
Input Voltage |
AC380V ± 20% |
|
|
7 |
Input Frequency |
50Hz ± 10% |
|
|
8 |
Output Voltage Range |
DC200 ~ 1000V |
|
|
9 |
Maximum Output Current per Channel |
Fast charge 250A/Super Charge 800A |
|
|
10 |
Constant Power Output Voltage Range |
DC300-1000V |
|
|
11 |
Peak Efficiency |
≥ 95%(50%-100 full load output power) |
|
|
12 |
Power Factor |
≥ 0.99(50%-100 full load output power) |
|
|
13 |
Voltage Stabilization Accuracy |
<0.5% |
|
|
14 |
Steady Flow Accuracy |
≤ ± 1% (output load 20%-100% rated range) |
|
|
15 |
Average Flow Unbalance Degree |
<± 5% |
|
|
16 |
Ripple Peak Peak |
≤ 1% |
|
|
17 |
ITHD |
≤ 5%(50%-100% full load output power) |
|
|
18 |
Insulation Resistance |
≥ 20MΩ |
|
|
19 |
Noise |
≤ 65dB (Grade Ⅱ) |
|
|
20 |
Heat Dissipation Mode |
Forced air cooling |
|
|
21 |
Communication Mode with Terminal Cabinet |
CAN communication |
|
|
22 |
Protection Level |
IP65 |
|
|
23 |
Usage Environment |
Indoor/Outdoor |
|
|
24 |
Operating Temperature |
-20 ℃ ~ +50 ℃ |
|
|
25 |
Storage Temperature |
-40 ℃ ~ +70 ℃ |
|
|
26 |
Relative Temperature |
5% to 95% |
|
|
27 |
Altitude |
≤ 2000m |
|
|
28 |
Installation Method |
Floor mounting |
|