Waterproofing and insulation for roofs are particularly important in construction. Roof-specific rock wool boards have excellent compressive strength and point load resistance, capable of meeting the weight requirements for construction and maintenance on the roof, as well as the weight of related equipment. There is no need for a separating layer between the waterproofing layer and the rock wool insulation layer, and they are compatible with various waterproofing membranes.

Product Specifications

Size

Density (kg/m³)

80-180

Thickness (mm)

30 -150

Dimensions (length × width)(mm × mm)

1200 × 600

Note: can be customized, if you need other specifications, please consult the company

Standard Specification-Enterprise Grade

Enterprise grade

Conform to standard

Characteristics and main indicators

HLGW-G801

National Standard

GB/T 19686-2015

High temperature resistance

Black cotton, high temperature resistance above 760 ℃

HLDL-G802

Low chlorine

M k≥1.6,CI -≤10mg/kg

HLGQ-G803

High strength

M k≥ 1.6, high temperature resistance above 649 ℃

Main performance and technical indicators

Serial Number

Terms

Test Item

Board index requirements

Felt index requirements

Test Method

1

GeneralProject

Appearance

The resin is evenly distributed, the surface is smooth, and there should be no scars, stains or damages that hinder the use.

The resin is evenly distributed, the surface is smooth, and there should be no scars, stains or damages that hinder the use.

Visual inspection

2

Average fiber diameter, μm

≤ 6.0

≤ 6.0

GB/T 5480

3

Slag ball (D> 0.25mm),%

≤ 7.0

≤ 7.0

GB/T 5480

4

Allowable deviation of length, mm

+10

-3

-3

GB/T 5480

5

Allowable deviation of width, mm

+5

-3

+5

-3

GB/T 5480

6

Allowable thickness deviation, mm

+3

-3

Negative difference not allowed

GB/T 5480

7

Density tolerance,%

10% (unit weight ≥ 80kg/m²)

10% (unit weight ≥ 80kg/m²)

GB/T 5480

8

Density tolerance,%

15% (bulk density <80kg/m²)

15% (bulk density <80kg/m²)

GB/T 5480

9

Combustion performance

Grade A

Grade A

GB 8624-2012

10

Acidity coefficient

≥ 1.6

≥ 1.6

GB/T 5480

11

Thermal conductivity, W/(m · K), 25 ℃

≤ 0.040

≤ 0.040

GB/T 10294

12

Moisture absorption rate by mass,%

≤ 0.5

≤ 0.5

GB/T 5480

13

Hydrophobic rate,%

≥ 98.0

≥ 98.0

GB/T 10299

14

SpecificProject

Water absorption,%

≤ 5

≤ 5

GB/T 5480

15

Short term water uptake (partial intrusion),kg/m²

≤ 0.5

≤ 0.5

GB/T 30805

16

Compression strength, kPa

≥ 80 (high strength type)

 

GB/T 13480

17

≥ 60 (first floor)

 

GB/T 13480

18

≥ 40 (not first floor)

 

GB/T 13480

19

Point load, N

≥ 700 (high strength type)

 

GB/T 30802

20

≥ 500 (first floor)

 

GB/T 30802

21

≥ 200 (not first floor)

 

GB/T 30802