Performance Index
Measurement accuracy (AT25℃)
|
Input Specifications
|
Range
|
Resolution (typical) ℃
|
Error (maximum)
|
|
PT100
|
-200~500
|
0.02
|
0.1
|
|
B
|
300~1820
|
0.15
|
1.4
|
|
S
|
0 ~ 1768
|
0.12
|
0.65
|
|
N
|
-200~1300
|
0.11
|
0.35
|
|
K
|
-180~1372
|
0.1
|
0.30
|
|
J
|
-180~760
|
0.1
|
0.2
|
|
T
|
-200~400
|
0.1
|
0.2
|
|
E
|
-50 ~ 1000
|
0.1
|
0.2
|
Note: The accuracy of the thermocouple should be based on the accuracy in the table and the cold end compensation accuracy should be plus 0.5℃.
Optimal accuracy after matching sensor (AT25℃)
|
Range ℃
|
Sensor model
|
Resolution ℃
|
Error ℃
|
|
-50 ~ 200
|
PT100
|
0.02
|
± 0.1 ℃
|
|
-70 ~ 300
|
± 0.5 ℃
|
Note 1: The PT100 sensor uses an integral sintered outer-wound ceramic platinum resistor. If other PT100 components are selected, the accuracy and stability depend on the stability and repeatability of the component.
Note 2: The sensor model and temperature range listed in the table are the most commonly used, the most stable, and the most representative sensor and temperature range. If you want to confirm other models and temperature ranges and accuracy, please contact with the manufacturer.
Electrical characteristics
The parameter conditions given in this table are: ambient temperature 25 ℃
|
Project
|
Condition
|
Typical value
|
|
Power consumption
|
Turn off backlight
|
<6mAh
|
|
Sampling time
|
-
|