Model |
INGSP-60K |
INGSP-120K |
INGSP-200K |
INGSP-300K |
INGSP-500K |
|
Photovoltaic input |
|||||
|
photovoltaic capacity |
60kWp |
120kWp |
240kWp |
300kWp |
500kWp |
|
Maximum PV capacity |
72kWp |
144kWp |
288kWp |
360kWp |
600kWp |
|
MPPT Operating Range |
200 ~ 550V |
200 ~ 550V |
200 ~ 550V |
200 ~ 550V |
200 ~ 550V |
|
Maximum input current |
2×75A |
4×75A |
8×75A |
10×75A |
16×75A |
|
Number of MPPT routes |
2 |
4 |
8 |
10 |
16 |
|
AC output |
|||||
|
Rated capacity |
60kVA |
120kVA |
240kVA |
300kVA |
500kVA |
|
Maximum output capacity |
72kVA |
144kWp |
288kWp |
360kWp |
630kWp |
|
Rated voltage |
AC400 |
AC400 |
AC400 |
AC400 |
AC400 |
|
Rated frequency |
50 to 60 |
50 to 60 |
50 to 60 |
50 to 60 |
50 to 60 |
|
Rated current |
90A |
173A |
346A |
456A |
721A |
|
Grid connection switching time |
≤ 20ms |
≤ 20ms |
≤ 20ms |
≤ 20ms |
≤ 20ms |
|
Peak Efficiency |
97.3 percent |
||||
|
Output line system |
3W+N+PE/3W+PE |
||||
|
Overload |
120%,1min;150%,10s |
||||
|
Battery System |
|||||
|
Battery capacity (not less than) |
120kWh |
215kWh |
430kWh |
645kWh |
1075kWh |
|
Charge and discharge power |
60kW |
100kW |
200kW |
300kW |
300kW |
|
Cell capacity |
144AH |
280AH |
280AH |
280AH |
280AH |
|
Maximum charge and discharge current |
72A |
140A |
140A |
140A |
140A |
|
Cell Type |
Lithium iron phosphate |
||||
|
Smoke alarm |
Smoke sensor |
||||
|
Extinguishing medium |
Aerosol/Heptafluoropropane |
||||
|
System parameters |
|||||
|
Operation mode |
Support constant power, constant voltage, constant current control |
||||
|
Basic functions |
Standby power, peak cutting and valley filling, photovoltaic absorption |
||||
|
Start the diesel engine |
I/O self-start |
||||
|
Grid-connected and off-grid switching |
Thyristor |
||||
|
Grid-connected and off-grid switching time |
≤ 20ms |
||||
|
Communication Interface |
CAN2.0, RS485, and EtherCAT |
||||
|
Communication Protocol |
Ethercat, ModbusRTU, Modbus-TCP, CAN2.0 |
||||
|
Display |
LCD |
||||
|
Isolation mode |
power frequency transformer |
||||
|
Cooling mode |
Air cooling/liquid cooling |
||||
|
Noise |
<70dB |
||||
|
Outdoor mode |
Outdoor cabinet/container |
||||
|
Protection level |
IP54 |
||||
|
Working temperature |
-20 ℃ ~ +45 ℃ |
||||
|
Permissible relative humidity |
0 ~ 95% (no condensation) |
||||
|
Allowable Altitude |
No derating below 2000m; derating operation from 2000m to 4000m |
||||
|
Certification Standards |
TUVCE,ENIEC61000-6-4-2019,ENIEC610006-2:2019 |
||||


京公网安备 11010802043282号