JSW-Series Walk-in Environmental Test Chambers for Fuel Cell Stacks
Negotiable
China
No. 1166 Tianlong Avenue, High-Tech Industrial Park, Jinniu District, Chengdu, Sichuan Province
+86 13568851915
Online Contact
Favorite
Product Introduction

Product Features:

Precise Climate Testing for Fuel Cell Stacks
Provides accurate environmental testing solutions tailored to hydrogen fuel cell stacks of varying power levels

Highly Targeted Design
Specifically designed to accommodate the vast majority of medium to large-scale fuel cell stacks on the market

Integrated System Architecture
Features an all-in-one design incorporating a hydrogen-air pre-cooling system and an ethylene glycol circulation system for complete support

Advanced Hardware-Software Integration
Ensures seamless coordination between the environmental chamber and the test bench through deep integration of control systems

Enhanced Safety
Equipped with a robust safety matrix and interlock response strategy to ensure safe and reliable testing operations

Product Parameters

Model

JSW-8T

JSW-15T

JSW-24T

Adapter stack

80KW

120KW

150KW

200KW

250KW

300KW

Hydrogen air pre-cooling device

JHAP26-T

JHAP39-T

JHAP412-T

JHAP515-T

JHAP618-T

Internal volume

8m³

15m³

24m³

Internal dimensions (D×W×H)

2000mm * 2000mm * 2000mm

2500mm * 2500mm * 2400mm

3200mm * 3000mm * 2500mm

Overall dimension of cabin (D×W×H)

3300mm * 2300mm * 2700mm

3800mm * 2800mm * 3100mm

4500mm * 3300mm * 3200mm

Size of refrigeration unit (D×W×H)

1700mm * 1350mm * 1700mm

2200mm * 1200mm * 2000mm

2200mm * 1400mm * 2000mm

Hydrogen air precooling size (D×W×H)

2250mm * 1250mm * 2600mm

2400mm * 1400mm * 2800mm

Pressure relief port size

0.24m ²

0.36m ²

0.45m ²

Installed power

90KW

113KW

155KW

170KW

183KW

Maximum current

135A

180A

248A

278A

304A

Cooling water flow

20m³/h

26m³/h

36m³/h

39m³/h

43m³/h

Temperature range

-40 ℃ ~ 90 ℃

Heating rate

≥ 1℃/min(-40℃ ~ 90℃, average in the whole process, with hydrogen fuel cell stack and tooling, no heat).

Cooling rate

≥ 1℃/min(-40℃ ~ 90℃, average in the whole process, with hydrogen fuel cell stack and tooling, no heat).

Temperature deviation

≤ ± 2.0℃ (no-load)

Temperature fluctuation

≤ ± 0.5℃ (static no heat load) ≤ ± 2.0℃ (dynamic test condition)

Temperature uniformity

≤ 2.0℃ (no-load, normal pressure, static)

Humidity range

20%RH~95%RH