JHM-Series (In-chamber Heat Dissipation) Hydrogen Fuel Cell System Environmental Test Chambers
Negotiable
China
No. 1166 Tianlong Avenue, High-Tech Industrial Park, Jinniu District, Chengdu, Sichuan Province
+86 13568851915
Online Contact
Favorite
Product Introduction

Product Features:

Precise and Reliable Temperature Control
Offers both in-chamber and external heat dissipation solutions to ensure accurate and stable temperature regulation throughout the testing process

Rapid Response to Multi-Physics Coupling
Equipped with proprietary software control systems and CFD-simulated air duct design, enabling the chamber to quickly and accurately respond to multi-physics interactions while maintaining tolerance within test standard limits

Remote Monitoring and Control
Integrated hardware and software systems allow for remote operation and real-time monitoring, greatly enhancing convenience and testing efficiency

Product Parameters

Model

JHM60T-I/LP(WP)

JHM70T-I/LP(WP)

JHM100T-I/LP(WP)

JHM120T-I/LP(WP)

JHM150T-I/LP(WP)

Adaptation system

120KW

150KW

200KW

250KW

300KW

Hydrogen pre-cooling device

JHP3-T

JHP4-T

JHP5-T

JHP6-T

Maximum fresh air volume

800m³/h

1200m³/h

Internal volume

60m³

72m³

100m³

120m³

150m³

Cabin dimension (D×W×H)

5700mm * 4300mm * 4300mm

6500mm * 4300mm * 4300mm

6800mm * 5300mm * 4700mm

7800mm * 5300mm * 4700mm

8050mm * 6300mm * 4700mm

Size of refrigeration unit (D×W×H)

2950mm * 1850mm * 2400mm × 2

2950mm * 1850mm * 2400mm × 2

2950mm * 1850mm * 2400mm × 2

2950mm * 1850mm * 2400mm × 3

2950mm * 1850mm * 2400mm × 3

Plateau unit size(D×W×H)

2800mm × 1700mm × 2500mm

2400mm * 1400mm * 2800mm

Size of fresh air unit (D×W×H)

3500mm × 1100mm × 1900mm

3500mm × 1200mm × 2000mm

Hydrogen pre-cooling size(D×W×H)

1800mm * 1000mm * 2600mm

2250mm * 1250mm * 2600mm

Humidity range

20%RH~95%RH

Temperature range during humidity test

20 ℃ ~ 85 ℃

Humidity deviation

(Humidity ≥ 75% RH)+2 ~-3% RH

Pipeline pressure range

Atmospheric pressure ~ 40kPa (about 6100m above sea level)

Pipeline pressure accuracy

± 2KPa (with load, after 3 minutes of dynamic, max. ≤ ± 5KPa within 3 minutes)

Pipeline air pressure reduction rate

Normal pressure ~ 40kpa ≤ 10min

Pipeline air pressure recovery rate

40kpa ~ normal pressure ≤ 10min

Pipeline pressure deviation

≤ ± 2KPa

Meet test criteria

GB/T24554-2022 "Fuel Cell Engine Performance Test Method"

GB/T25319-2010 "Technical Conditions of Fuel Cell Power Generation System for Automobiles"

GB/T28183-2011 "Test Methods of Fuel Cell Power Generation System for Passenger Cars"

GB/T33979-2017 "Proton Exchange Membrane Fuel Cell Power Generation System Low Temperature Characteristics Test Method"

GB/T28817-2012 "Test Methods for Single Cell of Polymer Electrolyte Fuel Cells"