Model |
TYD35/√3-0.01HF |
TYD35/√3-0.02HF |
TYD66/√3-0.01HF |
TYD66/√3-0.02HF |
TYD110/√3-0.01H |
TYD110/√3-0.02H |
TYD220/√3-0.005H |
TYD220/√3-0.01H |
TYD330/√3-0.005H |
TYD500/√3-0.005H |
TYD765/√3-0.005H |
TYD1000/√3-0.005H |
|
|
Maximum voltage of equipment (kV) |
405 |
40.5 |
72.5 |
72.5 |
126 |
126 |
252 |
252 |
363 |
550 |
800 |
1100 |
|
|
Rated frequency (Hz) |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
|
Rated capacitance (pF) |
10000 |
20000 |
10000 |
20000 |
10000 |
20000 |
5000 |
10000 |
5000 |
5000 |
5000 |
5000 |
|
|
Rated voltage factor/time |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
12/Continuous |
|
|
1.9/8h |
1.9/8h |
1.9/8h |
1.9/8h |
1.5/30s |
15/305 |
15/305 |
15/305 |
1.5/30s |
15/30s |
15/305 |
1.5/305 |
||
|
Rated power frequency withstand voltage (kV) |
95 |
95 |
160 |
160 |
230 |
230 |
460 |
460 |
510 |
740 |
975 |
1200 |
|
|
Rated lightning impulse withstand voltage (KV) |
200 |
200 |
350 |
350 |
550 |
550 |
1050 |
1050 |
1175 |
1675 |
2100 |
2400 |
|
|
Rated operating impulse withstand voltage (kv) |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
950 |
1300 |
1550 |
1800 |
|
|
Local discharge quantity (pC) under 1.2Um/√3 |
s5 |
≤ 5 |
≤ 5 |
s5 |
s5 |
≤ 5 |
≤ 5 |
≤ 5 |
≤ 5 |
s5 |
≤ 5 |
s5 |
|
|
Secondary winding (1aln) |
Accuracy level |
Level 02, Level 05 |
Level 02, Level 05 |
Level 02, Level 0.5 |
Class 02. Level 05 |
Class 02. Level 05 |
Class 02. Level 05 |
Level 02, Level 05 |
Level 02, Level 05 |
Level 02, Level 0.5 |
Level 02, Level 05 |
Class 02. Level 05 |
Level 02, Level 05 |
|
Rated output (VA) |
≤ 20 |
≤ 50 |
≤ 30 |
≤ 50 |
≤ 30 |
≤ 100 |
≤ 30 |
≤ 100 |
≤ 30 |
≤ 50 |
≤ 50 |
≤ 15 |
|
|
Secondary winding (2a2n) |
Accuracy level |
Level 05, 3P |
Level 05, 3P |
0.5 level, 3P level |
Level 05, 3P |
0.5 level, 3P level |
Level 05, 3P |
0.5 level, 3P level |
Level 05, 3P |
Level 05, 3P |
0.5 level, 3P level |
0.5 level, 3P level |
Level 05, 3P |
|
Rated output (VA) |
≤ 30 |
≤ 50 |
≤ 30 |
≤ 50 |
≤ 30 |
≤ 100 |
≤ 30 |
≤ 100 |
≤ 50 |
≤ 50 |
≤ 50 |
≤ 20 |
|
|
Secondary winding (3a3n) |
Accuracy level |
/ |
/ |
/ |
/ |
0.5 level, 3P level |
Level 05, 3P |
Level 05, 3P |
Level 05, 3P |
Level 05, 3P |
Level 05, 3P |
0.5 level, 3P level |
0.5 level, 3P level |
|
Rated output (VA) |
/ |
/ |
, |
/ |
≤ 30 |
≤ 100 |
≤ 30 |
≤ 100 |
≤ 50 |
≤ 50 |
≤ 50 |
≤ 20 |
|
|
Secondary winding (dadn) |
Accuracy level |
3P level, 6P level |
3P level, 6P level |
3P level, 6P level |
3P level, 6P level |
3P level, GP level |
3P level, 6P level |
3P level, 6P level |
3P level, 6P level |
3P level, 6P level |
3P level, 6P level |
3P level, 6P level |
3P level, 6P level |
|
Rated output (VA) |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
≤ 100 |
|
|
Product shape and installation dimensions |
Subject to confirmation drawings |
||||||||||||
|
Total product mass (kg) |
450 |
450 |
480 |
540 |
460 |
640 |
660 |
940 |
1150 |
1500 |
3400 |
7000 |
|