The performance parameter ratio of the two reversing valves RTO (take 300,000Nm³/h as an example
|
Performance parameters |
Rotary valve RTO |
Poppet valve RTO |
|
Processing air volume |
300000Nm³/h |
300000Nm³/h |
|
Reversing valve structure |
Rotary valve |
Poppet valve/butterfly valve |
|
Number of reversing valve |
3 |
27 |
|
Switching impact frequency of reversing valve |
Continuous operation without impact |
6.48 million times/year |
|
Number of heat storage beds |
36 beds. |
9 beds. |
|
Single room treatment air volume |
20000Nm³/h |
75000Nm³/h |
|
Flow cross-sectional area of single regenerator |
3m² |
14m² |
|
Single-chamber regenerative ceramic filling weight |
3300kg |
15600kg |
|
Number of burners |
3 |
5 |
|
Floor space (length * width) |
26m × 8m |
48m × 5m |