YYD Electromagnetic Flowmeter

Negotiable
China
No.106 Chunhan Road, Beiyuan Subdistrict, Yiwu City, Zhejiang Province
+86 579 85260678
Online Contact
Favorite
Product Introduction

Functions

Function Function Description
Parameter Setting Users can set parameters via three infrared keys without opening the cover
Display Language Supports Chinese and English display modes
LCD Display Instantaneous flow, instantaneous flow percentage, instantaneous flow progress bar, forward/reverse total, signal quality, operating status, flow velocity, time and date, etc.
Damping Damping time can be set between 0.1~200s
Unit Setting Supports total units m³, L, ten, kg, gal, Ib, ft³, time units s, min, h, day, flow units can be any combination of the above units
Pulse Output Pulse width: 50% duty cycle, 0.05, 0.1, 1, 20, 50, 100ms
Pulse equivalent: 1~1000
Pulse rate: 0.0001~10000pps
Communication Setting

The communication setting function allows selection of baud rate, parity bit and data format.

Baud rate: 2400, 4800, 9600

Parity: None, odd parity, even parity

Bidirectional Measurement Can measure forward and reverse flow
Batch Filling When the total reaches the preset value, digital output or relay output alarms
Preset Total Value Parameter setting or status input function allows the total to be preset to a set value or zero
Alarm Selection Function Alarms are divided into system alarms, process alarms (e.g. "empty pipe", "excitation broken"), setting alarms and warnings. Users can choose whether to alarm for each item.
Alarm Output For the alarm items selected in the alarm selection function, status output is performed when a fault occurs
Self-diagnosis When an alarm occurs, the alarm content will be displayed
Flow High/Low Alarm When the flow is greater than or less than the set value, an alarm is generated. In addition, an upper limit value and a lower limit value can be set. When the flow is greater than the upper limit or less than the lower limit, an alarm is output
Signal Quality Diagnosis Function This function allows monitoring the contamination level of electrodes and insulating materials. According to the contamination status, the status output will alarm the user. At this time, the electrodes need to be cleaned
Slurry Measurement Function Set excitation frequency to 25Hz to measure slurry, coal slurry, mud, mortar, pulp and other slurries
Low Conductivity Measurement Function Set excitation frequency to 25Hz to measure liquids with conductivity as low as 5μS/cm

Normal Operating Environment

Ambient Temperature -40℃~+60℃ Rated AC Voltage 85~265V.AC,50Hz (operating voltage range: 85~265V.AC)
Display Operating Temperature Range -20℃~+80℃ Rated DC Voltage 24V.DC (operating voltage range: 18~30V.DC)
Medium Temperature PTFE -35℃~+120℃ Vibration Conditions Vibration level must comply with IEC60068-2-6 (SAMA31.1) ≤1G (frequency ≤500Hz)
Note: Avoid installing the device on a highly vibrating ground (vibration frequency ≥500Hz), otherwise the device will be damaged.
PFA/F46 -35℃~+140℃
Neoprene -5℃~+65℃
Ambient Humidity 0~100%RH. It is recommended not to use the instrument for a long time in an environment with relative humidity greater than 95%