1 kV~35 kV Cross-linked Polyethylene Insulated Power Cable

Negotiable
China
No.2800 Guanghua Road, Minhang District, Shanghai
13918556500
Online Contact
Favorite

Product Introduction

Cross-linked polyethylene insulated power cables are suitable for power transmission and distribution systems at 35kV, 15kV, 10kV and below.

State Grid Shanghai Municipal Electric Power Company User-funded Agreement Inventory

State Grid Corporation of China 2017 First Batch of Substation Equipment (Including Cables) for Transmission and Transformation Projects State Grid Corporation of China 2018 First Batch of 35kV-110kV Expansion Supporting Project Substation Equipment Agreement Inventory Tender Procurement

State Grid Shandong Electric Power Company 2018 First Batch of Power Grid Materials Agreement Inventory State Grid Corporation of China Shanghai Power Grid, Jiangsu Power Grid, Zhejiang Power Grid, Tianjin Power Grid, Shandong Power Grid, Xinjiang Power Grid, Hunan Power Grid, Anhui Power Grid, Chongqing Power Grid Distribution Network Line Materials Agreement Inventory

Shanghai World Expo B Zone Central Enterprise Headquarters Energy Center Project, Shanghai Disneyland Core Area Energy Station Access Project, People's Bank of China Credit Reference Center Project, Baosteel Ergang Co., Ltd. Capacity Expansion Project

 

Product Parameters

Product Features Feature

This product is the mainstream cable with the widest application and the highest cost-performance ratio in current distribution systems. It offers excellent electrical performance, with insulation made of cross-linked polyethylene featuring high voltage resistance; high temperature resistance with a long-term allowable operating temperature of up to 90℃ and large current-carrying capacity; good mechanical and physical properties; long service life; convenient installation and wide applicability. In addition, the halogen-free, low-smoke, flame-retardant type of this product does not propagate flame after ignition, and features halogen-free, low-smoke, non-toxic and non-corrosive characteristics.

Working Conditions Working condition

1. Maximum operating temperature of conductor: 90℃.

2. Under short-circuit conditions (maximum duration not exceeding 5s), the maximum temperature of the cable conductor shall not exceed 250℃.

3. Installation ambient temperature: 0℃

4. Minimum bending radius of cable: not less than 20 times the outer diameter for single-core cables, and not less than 15 times the outer diameter for three-core cables.