WDet-5000TCN Total Cyanide Water Quality Online Analyzer

Negotiable
China
Room 301, Floor 3, Building 1, No. 22 Zhiren Street, Puyan Subdistrict, Binjiang District, Hangzhou, Zhejiang Province
0086-571-28322780
Online Contact
Favorite

Product Introduction

Product Overview

The WDet-5000TCN Total Cyanide Water Quality Online Analyzer is a newly developed online total cyanide monitoring instrument based on a brand-new metering technology platform, combined with self-developed distillation-colorimetric integrated technology. The working principle of this product complies with "HJ/T484-2009 Water Quality - Determination of Cyanide - Isonicotinic Acid-Barbituric Acid Spectrophotometric Method," featuring high reliability, low limit of quantification, and good stability.

Product Features

  • Adopts a brand-new quantification method and integrated valve design, effectively eliminating color and turbidity interference, with high precision and easy maintenance.
  • Equipped with multi-range automatic range switching and fully automatic calibration and cleaning functions, reducing manual intervention and ensuring measurement accuracy.
  • Supports fault self-diagnosis, real-time leakage monitoring with automatic lockout, and full-process operation information recording, ensuring safety and reliability.
  • Supports remote monitoring, maintenance, and software upgrades via network interface, enabling convenient and efficient operation and maintenance.
  • Equipped with a 7-inch Android touchscreen, offering an intuitive interface and smooth operation.
  • Provides multiple communication and signal interfaces, supporting on-demand function expansion to flexibly adapt to on-site requirements.

Application Fields

Suitable for pollution sources, industrial process water, municipal wastewater, and other fields.

Product Parameters

Test Method Isonicotinic Acid-Barbituric Acid Spectrophotometric Method Measurement Range 0~1.5/10/20mg/L (expandable)
Zero Drift ±5% Span Drift ±10%
Repeatability ≤5% Indication Error ±10%
Voltage Stability ±10% Measurement Interval On-the-hour measurement, interval time measurement, or trigger the instrument via Modbus
Calibration Supports manual and automatic calibration. Calibration cycle and time are configurable Ambient Temperature (5~40)℃, (65±20)%RH, non-condensing
Communication Interface Output: 1 channel (4-20) mA, RS232/RS485, 2 multifunctional relays; Input: 1 channel (4-20) mA, 2 digital inputs Power Supply AC(220±22)V, (50±0.5)Hz
Equipment Power 200W
Dimensions 580mm*513.1mm*1474.5mm (L*W*H) Weight 75kg