BSM4 busway system is developed by our company after the company has incorporated the advanced technology both home and abroad on fire-proof busway and it is fire-proof and intended for fire fighting.This product overcomes the problem such as traditional busway can not be used in fire-fighting conditions.Special material and special process enable this product completely meets the verification of preventing fire from spreading and acting as the fire damper in architectural structures.
BSM4 fireproof dense insulated Bus duct
Product Introduction
selection table
|
BSM4 type busbar selection table |
||||
|
Mode |
BSM4/4P |
BSM4/5P |
||
|
Overall size |
W(mm) |
H(mm) |
W(mm) |
H(mm) |
|
400 |
120 |
110 |
120 |
110 |
|
500 |
120 |
125 |
120 |
125 |
|
630 |
120 |
125 |
20 |
125 |
|
800 |
120 |
160 |
20 |
160 |
|
1000 |
120 |
175 |
20 |
175 |
|
1250 |
120 |
175 |
20 |
175 |
|
1600 |
120 |
220 |
20 |
220 |
|
2000 |
120 |
270 |
20 |
270 |
|
2500 |
120 |
325 |
20 |
325 |
|
3150 |
120 |
325 |
120 |
325 |
|
4000 |
120 |
375 |
120 |
375 |
|
5000 |
120 |
375 |
120 |
375 |
Technical parameters
|
Technical parameters of BsM3-2 Bus duct |
|||||||||||||||
|
EXECUTIVE STANDARD IEC61439-1:2011 GB7251.1-2013 GB7251.6-2015 |
|||||||||||||||
|
Ambient temperature |
(℃) |
|
|||||||||||||
|
Altitude |
|
Up to 2000M |
|||||||||||||
|
Protective grade |
|
IP66 |
|||||||||||||
|
Unitlength |
(m) |
O¹.6253.26 (0.562.3.2605-6 |
|||||||||||||
|
|
(V) |
660/1000 |
|||||||||||||
|
|
(V) |
380/660 |
|||||||||||||
|
Frequency |
(HZ) |
50-60 |
|||||||||||||
|
Rated current In |
(A) |
315 |
400 |
500 |
630 |
800 |
100 |
1250 |
60 |
200 |
2500 |
3150 |
4000 |
500 |
6300 |
|
ResistanceR20 |
(uΩ/ml) |
90.3 |
62.8 |
135.3 |
97.79 |
81.5 |
65.12 |
48.9 |
8.5 |
28.7 |
19.58 |
14.19 |
11.88 |
9.35 |
5.82 |
|
ReactanceX20 |
(uΩ/m) |
76.23 |
74.36 |
72.49 |
70.5 |
62.37 |
51.04 |
48.07 |
43.12 |
35.31 |
30.36 |
27.39 |
16.28 |
14.63 |
12.98 |
|
Total reactance 720 |
(uΩ/m) |
202.74 |
318.28 |
308.47 |
301.93 |
208.19 |
198.3 |
84.21 |
67.8 |
146.0 |
44.9 |
135. |
85.23 |
77.39 |
68.67 |
|
|
(mV/m |
78.2 |
|
84.3 |
|
78.7 |
|
78.5 |
|
|
|
73.2 |
66 |
63.7 |
|
|
=lcw |
(KA) |
15 |
30 |
80 |
150 |
||||||||||
|
|
(KA) |
30 |
63 |
176 |
330 |
||||||||||
|
Temperaturerise |
(K) |
GB/T7251 . 1和GB/T7251 . 6 |
|||||||||||||
|
Insulation resistance |
(MΩ) |
≥20 |
|||||||||||||
|
Electrical interval |
(mm) |
≥10 |
|||||||||||||
|
Creepage distance |
(mm) |
≥16 |
|||||||||||||
|
|
(Ω) |
<0.02 |
|||||||||||||
|
Dielectric property |
|
50Hz,3750V/lminno breakdown or flashover |
|||||||||||||
|
Installationway |
|
Vertical or horizonta |
|||||||||||||
|
Quantity of plug port |
|
Minimum 0.5/m(can provide double-layer plugging) |
|||||||||||||
|
Maximum fixed interval |
(m) |
4 |
3 |
3 |
|||||||||||
|
Balance load |
(kg/m) |
20 |
25 |
30 |
|||||||||||
|
Centralized load |
(kg) |
90 |
90 |
90 |
|||||||||||
Other products from this supplier

BSM10 series cast fire-resistant Bus duct

BSM7 Series Casting type fireproof and waterproof busway

BSM2 series aluminum conductor densely insulated Bus duct

BSM6 series high voltage common box Bus duct

BSM9 series copper conductor fire-resistant Bus duct

BSM3-2 series copper conductor energy-saving and environment-friendly densely insulated Bus duct

BSM3-1 series copper conductor energy-saving and environment-friendly densely insulated Bus duct

BSM1 series copper conductor denselyinsulated Busway

BSM11 series reinforced cast fire-resistant Bus duct

BSM6-1 pouring type high voltage common box Bus duct

BSM5 series small current lighting Bus duct

BSM3 series copper conductor energy-saving and environment-friendly densely insulated Bus duct
Related Products
Self-healing Low Voltage Capacitor
H-40.5/0.4~1.14kV New Energy Power Generation Dedicated High Voltage/Low Voltage Prefabricated Substation
Microgrid energy storage inverter module
IS(B)□-M·RL Series Oil-immersed 3D Transformer (Planar / 3D Wound Core)
Central Loose Tube Optical Fiber Cable GYXTW
Integrated Photovoltaic Energy Storage System
LVB Series 35-500kV Oil-immersed Inverted Current Transformer
Outdoor Pole-Mounted SF6 Gas-Insulated Load Break Switch
Prefabricated Substation (Hua-style)
220kV and Below Voltage Level Energy-saving Oil-immersed Power Transformers
Cap and Pin Porcelain Insulators