| Technical Specifications |
|
|
|
|
|
|
| Model |
|
SP R5KH3 |
SP R6KH3 |
SP R8KH3 |
SP R10KH3 |
SP R12KH3 |
| |
|
SP R5KAC3 |
SP R6KAC3 |
SP R8KAC3 |
SP R10KAC3 |
|
| Input PV (Hybrid only) |
|
|
|
|
|
|
| Maximum input power [W] |
|
7500 |
9000 |
10400 |
13000 |
15000 |
| Maximum input voltage (V) |
|
|
|
1000 |
|
|
| Starting input voltage [V) |
|
|
|
160 |
|
|
| Rated input voltage [V] |
|
|
|
720 |
|
|
| MPPT working voltage range [V] |
|
|
|
160-950 |
|
|
| Maximum input current (A) |
|
14/14 |
14/14 |
26/14 |
26/14 |
26/14 |
| Maximum short-circuit current [A] |
|
16/16 |
16/16 |
32/16 |
32/16 |
32/16 |
| Number of independent MP trackers |
|
|
2 |
2 |
2 |
2 |
| Number of strings per MPP tracker |
|
45292 |
45292 |
45323 |
45323 |
45323 |
| Battery connection |
|
|
|
|
|
|
| Battery Type |
|
Lithium battery (LFP) |
|
|
|
|
| Battery voltage range (V) |
|
150-600 |
|
|
|
|
| Maximum charge/discharge current (A) |
|
26 |
|
|
|
|
| Communication Interface |
|
CAN (communicate with inverter),RS485 (upgrade BMS) |
|
|
|
|
| AC input and output (grid) |
|
|
|
|
|
|
| Max. AC Input Power (VA) |
|
10000 |
12000 |
16000 |
16000 |
16000 |
| Maximum AC input current (per phase) [A] |
|
15.2 |
18.2 |
24.2 |
24.2 |
24.2 |
| Rated output power [W] |
|
5000 |
6000 |
8000 |
10000 |
12000 |
| Maximum output apparent power (VA) |
|
5500 |
6600 |
8800 |
11000 |
13200 |
| Rated output current (per phase) [A] |
|
7.2 |
8.7 |
11.6 |
14.5 |
17.4 |
| Maximum output current (A) |
|
8.8 |
10.6 |
14.1 |
17.6 |
21.2 |
| Rated grid voltage (V) |
|
|
3L/N/PE 380/220; 400/230; 415/240 |
|
|
|
| Rated grid frequency (Hz) |
|
|
50/60 |
|
|
|
| Power factor |
|
|
1 (from 0.8 lead to 0.8 hysteresis adjustable) |
|
|
|
| THDI |
|
|
<3 @ rated power |
|
|
|
| EPS output |
|
|
|
|
|
|
| Maximum output apparent power [VA) |
|
5000 |
6000 |
8000 |
10000 |
12000 |
| Peak output apparent power (60s) [VA] |
|
10000 |
12000 |
14000 |
15000 |
15000 |
| Maximum current (per phase) [A] |
|
7.2 |
8.7 |
11.6 |
14.5 |
17.4 |
| Rated output voltage [V] |
|
|
31/N/PE 400/230 |
|
|
|
| Rated output frequency [Hz] |
|
|
50/60 |
|
|
|
| Power factor |
|
|
1 (from 0.8 lead to 0.8 hysteresis adjustable) |
|
|
|
| THDv (linear load) |
|
|
<3% @ rated power |
|
|
|
| Switching time [ms] |
|
|
<20 |
|
|
|
| Efficiency |
|
|
|
|
|
|
| Euro efficiency |
|
0.978 |
0.978 |
0.98 |
0.98 |
0.98 |
| Maximum efficiency |
|
0.972 |
0.972 |
0.973 |
0.973 |
0.973 |
| Maximum battery charging efficiency (PV to BAT) (at full load) |
|
0.985 |
0.985 |
0.985 |
0.985 |
0.985 |
| Maximum battery discharge efficiency (BAT to AC) (at full load) |
|
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
| Protection |
|
|
|
|
|
|
| Insulation monitoring |
|
Yes |
|
|
|
|
| Residual current monitoring |
|
Yes |
|
|
|
|
| DC reverse polarity protection |
|
Yes |
|
|
|
|
| Anti-island protection |
|
Yes |
|
|
|
|
| AC Short Circuit Protection |
|
Yes |
|
|
|
|
| AC Overcurrent/Overvoltage Protection |
|
Yes |
|
|
|
|
| DC switch |
|
Yes |
|
|
|
|
| Speed sensor |
|
DC: TypeIl, /AC: Type Il |
|
|
|
|
| AFCI |
|
Optional (available Q3 2022) |
|
|
|
|
| General data |
|
|
|
|
|
|
| Dimensions (WxHxD) [mm] |
|
449*519*198 |
|
|
|
|
| Weight (kg) |
|
28.5 |
|
|
|
|
| Installation |
|
Wall-mounted |
|
|
|
|
| Topology |
|
No transformer |
|
|
|
|
| Cooling method |
|
Natural |
|
|
Fan cooling |
|
| Noise emission (dB) |
|
35 |
|
|
45 |
|
| Maximum working height [m] |
|
2000 |
|
|
|
|
| Operating temperature range (° C) |
|
-25 to 60 |
|
|
|
|
| Humidity (non-condensing) |
|
0% to 100% |
|
|
|
|
| Protection level |
|
IP65 |
|
|
|
|
| Standby consumption [W] |
|
<15 |
|
|
|
|
| Monitoring module |
|
WiFi,LAN,4G, GPRS (optional) |
|
|
|
|
| Communication |
|
2 * RS485,DRM, ripple control, USB |
|
|
|
|
| Display |
|
LCD,App, website |
|
|
|
|
| |
|
|
|
|
|
|
| Standards compliance (more information available on request) |
|
|
|
|
|
|
| Security |
|
EN 62109-1, EN 62109-2, EN 62477-1 |
|
|
|
|
| EMC |
|
lEC61000-6-1,IEC61000-6-3 |
|
|
|
|
| Grid Regulation |
|
Vde-ar-n 4105,CEI 0-21 |
|
|
|
|