ZWNS Condensing Vacuum Hot Water Boiler
Negotiable
China
No. 21, Chuangye West Road, Xinbei District, Changzhou City, Jiangsu Province
8618015810256
Online Contact
Favorite
Product Introduction
  • NOx Emission Value: ≤30mg/m³, equipped with ultra-low NOx burner.
  • Thermal Efficiency: 98-104%, condensing boiler. The lower the return water temperature, the higher the efficiency.

Product Features and Advantages

  • Negative Pressure Operation, No Inspection Required:
    It does not fall under the "Pressure Vessel Safety Regulations," exempting it from inspection, saving costs.

  • Vacuum Environment Prevents Scaling:
    The boiler operates in a high-vacuum, oxygen-free environment using softened heat transfer water, which does not need to be replaced during the boiler’s lifetime, preventing scaling.

  • Efficient Insulation with Minimal Heat Loss:
    Uses new lightweight insulation materials that minimize heat loss and provide excellent thermal performance.

  • Comprehensive Protection for Peace of Mind:
    Equipped with over-temperature, overpressure, and leak protection systems, ensuring safe and stable operation.

  • Fully Assembled for Quick Installation:
    The compact and elegant design is fully assembled and ready for installation, making the process quick and shortening construction time.

  • High-Efficiency Combustion with Low NOx Emissions:
    Equipped with a renowned brand burner for complete combustion, high thermal efficiency, and low fuel consumption, achieving low NOx emissions.

  • Multi-Purpose Design with Multiple Coil Technology:
    Can be configured with heat exchangers for heating and hot water applications, significantly reducing system complexity and saving on equipment and investment.

  • Condensing Heat Exchange for Fuel Savings:
    A condenser can be installed at the flue outlet to fully absorb the latent heat of the flue gases, resulting in significant fuel savings and pushing thermal efficiency beyond 100%.

  • Corrosion-Resistant Special Steel Condenser:
    To prevent acid corrosion caused by flue gas condensation, ND steel and other special steels are used for the finned tubes, improving both corrosion resistance and heat transfer efficiency.

  • Intelligent Multi-Unit Group Control:
    Features a colorful touchscreen PLC control system for easy operation, automatic fault diagnosis, and fully automatic operation.

Product Parameter
 (Model)  (Rated Power) MW  (AC Heating Inlet/Outlet Temp) ℃  (AC Heating Water Flow) m³/h  (AC Heating Pressure Loss) kPa  (Radiator Heating Inlet/Outlet Temp) ℃  (Radiator Heating Water Flow) m³/h  (Radiator Heating Pressure Loss) kPa  (Thermal Efficiency) %  (Applicable Fuel)  (Natural Gas Consumption) Nm³/h (LPG Consumption) Nm³/h (Light Diesel Consumption) kg/h  (Power Consumption) kW  (Voltage) V  (Weight) T  (Water Capacity) m³  (NOx Emission Value)
ZWNS 0.35 0.35 50/60 30 10 60/80 15 10 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 36.9 13 30.6 1.5 220、380/50Hz 3.3 0.65 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 0.7 0.7 50/60 60 18 60/80 30 18 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 72.2 25.3 60.4 2.2 220、380/50Hz 3.46 1.5 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 0.93 0.93 50/60 80 20 60/80 40 20 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 9.59 33.5 80.5 2.2 220、380/50Hz 4.84 2 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 1.17 1.17 50/60 90 20 60/80 45 20 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 110.6 38.1 91.9 5.5 220、380/50Hz 5 2.2 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 1.4 1.4 50/60 120 21 60/80 60 21 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 144.2 50.5 120.6 5.5 220、380/50Hz 5.3 2.2 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 1.75 1.75 50/60 150 29 60/80 75 29 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 180.2 62.6 151 5.5 220、380/50Hz 8 3.7 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 2.1 2.1 50/60 180 38 60/80 90 38 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 216.2 75.5 180.6 9.2 220、380/50Hz 8.36 3.8 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 2.34 2.34 50/60 200 38 60/80 100 38 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 241.3 84.5 201.9 9.2 220、380/50Hz 8.76 3.8 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 2.8 2800 50/60 240 40 60/80 120 40 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 288.3 101.4 241.6 9.2 220、380/50Hz 10 4.6 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 3.5 3500 50/60 300 42 60/80 150 42 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 360.9 127.2 301.5 15 220、380/50Hz 13.3 8.3 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 4.2 4200 50/60 360 43 60/80 180 43 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 434.7 152.1 362.4 15 220、380/50Hz 13.6 8.5 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 5.6 5600 50/60 480 45 60/80 240 45 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 577.5 203.3 483.3 22 220、380/50Hz 16.8 14 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³
ZWNS 7 7000 50/60 600 48 60/80 300 48 98%-104% (The lower the return water temperature, the higher the efficiency) natural gas/liquefied gas/light diesel oil 722.2 253.6 603.6 25 220、380/50Hz 26.4 13.5 ≤150mg/Nm³/≤80mg/Nm³/≤30mg/Nm³