Temperature/Water Hold-Up/Flow Logging Tool (HTF02)
Negotiable
China
No. 5, West of Qinling 3rd Road, Caotang Science and Technology Industrial Base, High-tech Zone, Xi’an, Shaanxi Province
+86 18792563409
Online Contact
Favorite
Product Introduction

The Temperature/Water Hold-Up/Flow Logging Tool (HTF02) is an instrument that integrates three types of sensors and electronic components into a single short section for measuring well temperature, water hold-up, and flow rate. The electronic circuitry processes the signals from the three sensors. The lower end of the instrument is connected to the flowmeter mechanical body for flow rate measurement. Depending on the logging requirements, either a continuous flowmeter mechanical body or a full-bore flowmeter mechanical body can be selected.

The instrument has a simple structure and is easy to operate.

Product Specifications

Outer diameter

43mm(1 11/16 ")

Maximum operating temperature

175°C (347 °F)

Maximum working pressure

103MPa(15000Psi)

Connection length

452mm(17.79 ")

Zero long

Well temperature: 183mm(7.2 ")

Water holdup: 135mm(5.31 ")

Weight

2Kg(4.4lbs)

Operating voltage

18VDC

Working current

45±3mA

Instrument Bus Protocol

WSTbus

Water holdup measurement range

0 to 45%

Water holdup accuracy

0.01

Temperature measurement range

0~175 ℃

Temperature Resolution

0.01 ℃

Temperature accuracy

± 2 ℃

Response time

<0.5S

Flow output

10 pulses/Revolution

Logging velocity

>400m/h

Upper docking standard

WSDJ-GoA-1A