This product complies with G8-7251.6-2015 and IEC60439 standards, with a rated working voltage of 1000V, a rated current of 400~6300A, a plug-in box tapping current of 20~1250A, and a maximum protection level of up to IP66. It is suitable for a variety of power supply systems such as three-phase three-wire, three-phase four-wire, and three-phase five-wire. It can be widely used in large commercial plazas, high-rise buildings, intelligent buildings, gymnasiums, industrial plants, hospitals and other important occasions. It is a low-voltage bus duct system with the best comprehensive performance.
TE/LE-series intensive bus duct
Basic parameters
|
Executive standards |
IEC/EN60439.1/2 GB7251.6-2015 UK BS etc |
|
Certificate |
CQC |
|
System |
Three-phase three-wire, three-phase four-wire, three-phase five-wire system |
|
Ambient temperature |
No more than +40 ℃,24 hours average no more than +35 ℃ |
|
Protection level |
IP54/IP66 |
|
Installation method |
Horizontal installation/vertical installation |
|
Conductor material |
Copper Busbars are Tin Plated (or Silver), Aluminum Busbars are Special Surface Treatment |
|
Rated insulation voltage UiAC(V) |
1000 |
|
Rated operating voltage UeAC (V) |
1000 |
|
Rated frequency f (Hz) |
50/60 |
|
Bus current (A) |
400~6300 |
|
Plug box current (A) |
20A ~ 1250A |
|
Voltage category/pollution level |
III/3 |
TE Parameter List (Copper Busbar System)
|
Rated current in(A) |
Short-time withstand current Icw(kA) |
Peak withstand current Ipk(kA) |
Overall dimension |
|
|
Width W(mm) |
Height H(mm |
|||
|
400 |
30 |
63 |
115 |
94 |
|
500 |
30 |
63 |
115 |
94 |
|
630 |
50 |
105 |
115 |
94 |
|
800 |
50 |
105 |
115 |
104 |
|
1000 |
50 |
105 |
115 |
119 |
|
1200 |
50 |
105 |
115 |
134 |
|
1600 |
50 |
105 |
115 |
174 |
|
1600 |
80 |
176 |
115 |
174 |
|
2000 |
80 |
176 |
115 |
194 |
|
2500 |
80 |
176 |
115 |
244 |
|
3150 |
80 |
176 |
115 |
348 |
|
4000 |
80 |
176 |
115 |
388 |
|
4000 |
100 |
220 |
115 |
388 |
|
4500 |
100 |
220 |
115 |
428 |
|
5000 |
100 |
220 |
115 |
488 |
|
6300 |
100 |
220 |
115 |
695 |
List of LE Parameters (Aluminum Busbar System)
|
Rated current In(A) |
Short-time withstand current Icw(kA) |
Bias withstand current lpk(kA) |
Overall dimension |
|
|
Width W(mm) |
Height H(mm) |
|||
|
400 |
30 |
63 |
115 |
94 |
|
500 |
30 |
63 |
115 |
104 |
|
630 |
30 |
63 |
115 |
114 |
|
800 |
30 |
63 |
115 |
134 |
|
1000 |
30 |
63 |
115 |
154 |
|
1200 |
30 |
63 |
115 |
174 |
|
1600 |
30 |
63 |
115 |
214 |
|
1600 |
80 |
176 |
115 |
214 |
|
2000 |
80 |
176 |
115 |
234 |
|
2500 |
80 |
176 |
115 |
254 |
|
3150 |
80 |
176 |
115 |
374 |
|
3200 |
80 |
176 |
115 |
374 |
|
4000 |
80 |
176 |
115 |
534 |