S11-M series three-phase double-winding no-load voltage regulation distribution transformer |
||||||||||||||
|
Rated capacity (kVA) |
Voltage combination (kV) |
Bonding group |
Loss (W) |
No-load current (%) |
Short circuit impedance (%) |
Weight (kg) |
Exterior dimension (mm) |
Gauge mm |
||||||
|
High pressure |
Low pressure |
No-load |
Load |
Oil weight |
Total weight |
Long |
Wide |
High |
||||||
|
30 |
6 6.3 10 10.5 11±5 Or ± 2 × 2.5% |
0.4 |
Yyn0 Dyn11 |
100 |
630/600 |
2.3 |
4 |
60 |
265 |
750 |
560 |
870 |
400 × 400 |
|
|
50 |
130 |
910/870 |
2 |
85 |
350 |
780 |
560 |
880 |
400 × 400 |
|||||
|
63 |
150 |
1090/1040 |
1.9 |
95 |
410 |
800 |
570 |
910 |
400 × 400 |
|||||
|
80 |
180 |
1310/1250 |
1.9 |
100 |
460 |
820 |
580 |
940 |
400 × 400 |
|||||
|
100 |
200 |
1580/1500 |
1.8 |
110 |
515 |
860 |
600 |
960 |
400 × 400 |
|||||
|
125 |
240 |
1890/1800 |
1.7 |
120 |
600 |
880 |
650 |
1040 |
550 × 550 |
|||||
|
160 |
280 |
2310/2200 |
1.6 |
130 |
660 |
900 |
700 |
1100 |
550 × 550 |
|||||
|
200 |
340 |
2730/2600 |
1.5 |
150 |
770 |
1070 |
730 |
1150 |
550 × 550 |
|||||
|
250 |
400 |
3200/3050 |
1.4 |
175 |
905 |
1170 |
780 |
1170 |
550 × 550 |
|||||
|
315 |
480 |
3830/3650 |
1.4 |
200 |
1030 |
1320 |
840 |
1190 |
550 × 550 |
|||||
|
400 |
570 |
4520/4300 |
1.3 |
225 |
1235 |
1360 |
870 |
1220 |
660 × 660 |
|||||
|
500 |
680 |
5410/5150 |
1.2 |
280 |
1470 |
1480 |
950 |
1250 |
660 × 660 |
|||||
|
630 |
810 |
6200 |
1.1 |
4.5 |
325 |
1805 |
1560 |
990 |
1290 |
660 × 660 |
||||
|
800 |
980 |
7500 |
1 |
370 |
2120 |
1660 |
1070 |
1350 |
820 × 820 |
|||||
|
1000 |
1150 |
10300 |
1 |
470 |
2390 |
1730 |
1150 |
1480 |
820 × 820 |
|||||
|
1250 |
1360 |
12000 |
0.9 |
520 |
2900 |
1850 |
1350 |
1550 |
820 × 820 |
|||||
|
1600 |
1640 |
14500 |
0.8 |
610 |
3600 |
2000 |
1400 |
1600 |
820 × 820 |
|||||
|
Note: For transformers with a rated capacity of 500kVA and below, the load loss value above the slash in the table applies to the Dyn11 connection group, and the load loss value below the slash applies to the Yyn0 connection group. |
||||||||||||||
1/1
S11-M series three-phase double-winding no-load voltage regulation distribution transformer
Negotiable
China
No. 84, Hushan Road, Jiangshan City, Zhejiang Province
+86 0571-88360525
gjywb@jsb-zj.com
Product Introduction
Other products from this supplier
Negotiable
SBH15-30-1600 10 series three-phase amorphous alloy transformer
Negotiable
S13-M series three-phase double-winding no-load voltage regulation distribution transformer
Negotiable
S11-MR series three-phase double-winding no-load voltage regulation distribution transformer
Negotiable
S9-MR series three-phase double-winding no-load voltage regulation distribution transformer
Negotiable
S9-M series three-phase double-winding no-load voltage regulation distribution transformer
Negotiable
S11-M series three-phase double-winding no-load voltage regulation 20kV distribution transformer
Negotiable
35kV double-winding on-load voltage regulation power transformer
Negotiable
35kV double-winding no-load voltage regulation power transformer
Negotiable
630-2500/35 series three-phase double-winding no-load voltage regulation power transformer
Negotiable
50-1600/35 series three-phase double-winding no-load voltage regulation distribution transformer
Negotiable
66kV double-winding on-load voltage regulation power transformer
Negotiable
66kV double-winding no-load voltage regulation power transformer
Related Products
All-Black Solar Panel - 54X 410-430W
Negotiable
10kV, 20kV, 35kV series resin cast dry-type power transformer
Negotiable
220kV and Below Series Power Transformers
Negotiable
Microcomputer Protection and Substation Automation
Negotiable
220kV Composite Outdoor Cable Terminal
Negotiable
TE/LE-series intensive bus duct
Negotiable
220kV double-winding no-load voltage regulation power transformer
Negotiable
YB □(ZBW27)-12/0.4(F·R) Outdoor Pre-assembled Substation (European Style)
Negotiable
Suspension Fittings
Negotiable
Vacuum Interrupter
Negotiable
CM On-Load Tap Changers
Negotiable
PRS-753 Line Protection
Negotiable