Ring Main Unit JSR6-17.5 Gas-insulated Metal-enclosed Switchgear
EXW
$2,863.55-11,454.61 /Unit
China
No. 269, Xuexi South Road, Gaohong Town, Hangzhou City, Zhejiang Province
+86-0571-2365 8328
Online Contact
Favorite
Product Introduction

Product Features

  1. The primary components adopt a fully sealed design, completely enclosed within a sealed gas tank welded from stainless steel plates, filled with 0.04MPa SF6gas as the insulating medium, achieving a protection rating of IP67. This fully shields the switchgear from external environmental and climatic influences, enabling reliable operation in harsh environments such as basements, plateaus, permafrost, coastal areas, humid regions, and deserts, with maintenance-free performance.

Features a modular design with fully insulated and shielded busbars and cross or T-shaped connectors, facilitating easy installation and flexible expansion. No gas filling is required during on-site cabinet assembly, and the gas leakage rate is extremely low.

  1. Supports both manual and electric operation, with a mature and reliable operating mechanism, equipped with comprehensive mechanical and electrical interlocking to effectively prevent personal injury and equipment damage due to misoperation.
  2. Compact design structure significantly reduces the volume compared to traditional air-insulated switchgear, with a footprint reduction of 30% to 70%, improving space utilization and effectively lowering overall project costs.
  3. Specially designed to allow insulation testing of cables without opening the lower door of the ring main unit, meeting diverse customer needs. Based on microprocessor protection and system technology, it integrates protection, control, metering, monitoring, and communication functions, fulfilling comprehensive automation requirements and enabling fully unattended operation.
Product Parameters

Name

Unit

Load switch unit

Circuit Breaker Unit

Rated voltage

kV

17.5

 

Rated frequency

Hz

50/60

 

Rated current

A

100/200/400/630

 

Rated short-time power frequency withstand voltage

Phase-to-phase, phase-to-ground

kV

38

 

Isolation fracture

 

45

 

Rated lightning impulse withstand voltage

Phase-to-phase, phase-to-ground

kV

95

 

Isolation fracture

 

110

 

Power frequency withstand voltage of control and auxiliary circuit (1min)

kV

2

 

Rated short-circuit breaking current

kA

-

21

Rated short-time withstand current/rated short-circuit duration

kA/S

45768

 

Rated peak withstand current

kA

54.6

 

Rated breaking and closing current

kA

54.6

 

Protection grade of solid cabinet body/protection grade of cabinet body

 

IP67/IP4X

 

Partial discharge of solid insulation components (measured at 1.2Ur)

pc

≤ 5

 

Local discharge capacity of the whole cabinet (measured value under 1.2Ur)

pc

≤ 20