Dual Conductor Heating Cable
Negotiable
China
**Dazhu County Industrial Park, Sichuan Province**
0818-6226666
Online Contact
Favorite
Product Introduction

The heating cable, commonly known as a geothermal cable, includes the Chndo dual conductor heating cable, which differs from the single conductor heating cable. It consists of two cores—a metal heating wire and a copper conductor—welded together. The dual conductor heating cable forms a closed loop, allowing the cable core to be folded back at the tail end of the heating cable. During installation, only the connection end of the heating cable needs to be wired. Since the dual conductor heating cable forms its own loop with all connections at one end, during construction, only the connection end needs to be linked to the power supply, and the tail end does not require wiring. It can be placed arbitrarily based on specific conditions. Compared to the single conductor heating cable, it significantly reduces construction difficulty, mitigates electromagnetic radiation, and is increasingly favored by users.

Product Parameters

Serial Number

(W) Power

Cable type

(V) Voltage

Length standard (M)

Power per meter (W/M)

Total resistance value (Ω)

1

3300

TXLP/2/17

220V

194

17

14.7

2

3000

TXLP/2/17

220V

176

17

16.1

3

2800

TXLP/2/17

220V

165

17

17.3

4

2600

TXLP/2/17

220V

153

17

18.6

5

2400

TXLP/2/17

220V

141

17

20.2

6

2200

TXLP/2/17

220V

129

17

22

7

2050

TXLP/2/17

220V

118

17

24.2

8

1700

TXLP/2/17

220V

100

17

28.5

9

1370

TXLP/2/17

220V

81

17

35.3

10

1250

TXLP/2/17

220V

74

17

38.7

11

1000

TXLP/2/17

220V

59

17

48.4

12

840

TXLP/2/17

220V

49

17

57.6

13

700

TXLP/2/17

220V

41

17

69.1

14

600

TXLP/2/17

220V

35

17

80.7

15

500

TXLP/2/17

220V

29

17

96.8

16

400

TXLP/2/17

220V

24

17

121

17

300

TXLP/2/17

220V

18

17

161.3