WP5D Horizontal Woltman Water Meter Series DN50~500

Negotiable
China
No.355 Hongxing Road, Jiangbei District, Ningbo City, Zhejiang Province
+86-574-88195820
Online Contact
Favorite
Product Parameters

Technical parameters

Flow parameters

Caliber DN

Q3/Q1

Overload flow Q4

Common flow Q3

Demarcation flow Q2

Minimum flow Q1

Min reading

Max reading

m3 /h

L/h

m3

50

200

78.75

63

504.0

315.0

0.0005

999 999

160

630.0

393.8

125

512.0

320.0

80

250

125

100

640.0

400.0

200

800.0

500.0

160

1000.0

625.0

100

250

200

160

1024.0

640.0

200

1280.0

800.0

160

1600.0

1000.0

150

250

500

400

2560.0

1600.0

0.005

9 999 999

200

3200.0

2000.0

160

4000.0

2500.0

200

250

787.5

630

4032.0

2520.0

200

5040.0

3150.0

60

6300.0

3937.5

250

250

1250

1000

6400.0

4000.0

0.02 (0.025 dry type)

99 999 999

200

8000.0

5000.0

160

10000.0

6250.0

300

250

2000

1600

10240.0

6400.0

200

12800.0

8000.0

160

16000.0

10000.0

400

250

3125

2500

16000.0

10000.0

200

20000.0

12500.0

160

25000.0

15625.0

500

250

5000

4000

25600.0

16000.0

200

32000.0

20000.0

160

40000.0

25000.0

Maximum allowable error: the maximum allowable error in the low area (Q1 ≤Q<Q2) is ± 5%; the maximum allowable error in the high area (Q2 ≤Q≤ Q4) is ± 2%.

Appearance size

Note: The dimensions and weight are for reference only, and the actual product shall prevail.

Caliber DN

Long L

High H

High G

Connecting flange

Weight

Diameter D of flange

Center diameter D1 of bolt hole

Number of bolts

mm

Unit

Kg

50

200

210

320

165

125

4xM16

9.5

80

225

260

350

200

160

8xM16

11.6

100

250

270

370

220

180

8xM16

14.5

150

300

310

520

285

240

8xM20

27.5

200

350

370

620

340

295

8xM20

45

250

450

490

710

395

350

12xM20

83

300

500

510

750

445

400

12xM20

99

400

600

630

830

565

515

16xM24

163

500

800

740

930

670

620

20xM24

270

Note:

1) Flange connection shall be in accordance with the provisions of GB/T 17241.6-2008/XG-2011 PN10 integral cast iron flange size;

2) The height G dimension is necessary to disassemble the movement.

Performance parameters

Temperature class

T30

Pressure loss rating

p10, p25, p40

Pressure rating

MAP16

Accuracy class

Level 2

Flow field sensitivity level

UO/D0