Electromagnetic Water Meter LXE-40~600
Negotiable
China
No.355 Hongxing Road, Jiangbei District, Ningbo City, Zhejiang Province
+86-574-88195820
Online Contact
Favorite
Product Parameters

Technical parameters

Flow parameters

Caliber DN

Q3/Q1

Overload flow Q4

Common flow Q3

Demarcation flow Q2

Minimum flow Q1

Min reading

Max reading

m3 /h

L/h

m3

40

400

31.25

25

100.0

62.5

0.0001

99

999

999

250

160.0

100.0

50

400

50

40

160.0

100.0

250

256.0

160.0

80

400

78.75

63/100

252.0/400.0

157.5/250.0

250

403.2/640.0

252.0/400.0

100

400

125

100/160

400.0/640.0

250.0/400.0

250

640.0/1024.0

400.0/640.0

150

400

312.5

250/400

1000.0/1600.0

625.0/1000.0

250

1600.0/2560.0

1000.0/1600.0

200

400

500

400/630

1600.0/2520.0

1000.0/1575.0

250

2560.0/4032.0

1600.0/2520.0

250

400

787.5

630

2520.0

1575.0

250

4032.0

2520.0

300

400

1250

1000

4000.0

2500.0

250

6400.0

4000.0

400

250

3125

2500

16000.0

10000.0

500

250

4375

3500

22400.0

14000.0

600

250

5000

4000

25600.0

16000.0

Maximum allowable error: the maximum allowable error in the low area (Q1 ≤Q<Q2) is ± 5%; the maximum allowable error in the high area (Q2 ≤Q≤ Q4) is ± 2%.

Appearance size

Note: The dimensions and weight are for reference only, and the actual product shall prevail.

Caliber DN

Long L

Width B

High H

Connecting thread

mm

d

D

40

200/245

245

350

R1 1/2

G2B

Caliber DN

Long L

Width B

High H

Connecting flange

Flange diameter D

Bolt hole center diameter D1

Number of bolts

mm

Only

50

200/280

245

356

165

125

4xM16

80

200/370

245

390

200

160

8xM16

100

250/370

245

406

220

180

8xM16

150

300/500

285

466

285

240

8xM20

200

350

340

510

340

295

8xM20

250

450

395

572

395

350

12xM20

300

500

445

622

445

400

12xM20

400

600

565

751

565

515

16xM28

500

600

670

856

670

620

20xM28

600

600

780

942

780

725

20xM30

Performance parameters

Temperature class

T50

Electromagnetic environment level

E2

Maximum allowable pressure

1.6MPa

Communication mode

NB-loT, LoRa, 4G, RS-485, M-Bus, etc

Environmental grade

O

Accuracy class

Level 2

Material Parameters

Sensor housing material

304 stainless steel

Converter housing material

304 stainless steel

Flange material

304 stainless steel

Conduit Material

304 stainless steel

Lining material

Rubber

Communication cable

1.5m

Electrode material/type

316L Standard

Grounding ring/ground stud

No grounding ring/standard ground stud required