JHM Series (External Heat Dissipation) Hydrogen Fuel Cell System Environmental Test Chamber

Negotiable
China
18030810556
Online Contact
Favorite

Product Introduction

I. Model Description

JHM15T-O/LP/WP

JHM-Product Series Number | 15-Working Chamber Volume (Unit: M³) | T-Minimum Temperature -40°C

O: External Heat Dissipation | LP: Ducted Low Pressure | WP: Full Chamber Low Pressure

II. Main Test Items

◆ Low Temperature Test (Low Temperature Storage, Start-up, Performance)

◆ High Temperature Test (High Temperature Storage, Start-up, Performance)

◆ Damp Heat Test (High Temperature Damp Heat)

◆ Temperature Altitude Test (Air Pressure Simulation)

◆ Hydrogen Fuel Cell System -30°C Cold Start Test

III. Compliant Test Standards

◆ GB/T 24554-2022 "Fuel Cell Engine Performance Test Methods";

◆ GB/T 25319-2010 "Technical Specifications for Fuel Cell Power Generation Systems for Automobiles";

◆ GB/T 28183-2011 "Test Methods for Fuel Cell Power Generation Systems for Buses";

◆ GB/T 33979-2017 "Test Methods for Low Temperature Characteristics of Proton Exchange Membrane Fuel Cell Power Generation Systems";

◆ GB/T 28817-2012 Test Methods for Single Cells of Polymer Electrolyte Fuel Cells;

Model JHM15T-O/LP(WP) JHM24T-O/LP(WP)
Compatible System 120KW 150KW 200KW 250KW 300KW
Hydrogen Pre-cooling Unit HY3-TC HY4-TC HY5-TC HY6-TC
Maximum Fresh Air Volume 800m³/h 1200m³/h 1800m³/h
Internal Volume 15m³ 24m³
Chamber External Dimensions (D×W×H) 3800mm*2800mm*3100mm 4500mm*3300mm*3200mm
Refrigeration Unit Dimensions (D×W×H) 2200mm*1200mm*2000mm 2200mm*1400mm*2000mm 2950mm*1850mm*2400mm
High Altitude Unit Dimensions (D×W×H) 2800mm×1700mm×2500mm
Fresh Air Unit Dimensions (D×W×H) 3500mmx1100mmx1900mm 3500mmx1200mmx2000mm
Hydrogen Pre-cooling Dimensions (D×W×H) 2200mm*1250mm*2600mm 2400mm*1250mm*2600mm
Temperature Range -40°C~90°C
Heating Rate ≥1°C/min (within the range of -40°C~+90°C, full-process average, with loaded hydrogen fuel cell system and tooling, system without heat dissipation).
Cooling Rate ≥1°C/min (within the range of -40°C~+90°C, full-process average, with loaded hydrogen fuel cell system and tooling, system without heat dissipation).
Temperature Deviation ≤±2.0°C
Temperature Fluctuation ≤±0.5°C (static without thermal load) ≤±2.0°C (dynamic test conditions)
Temperature Uniformity ≤2.0°C (no load, normal pressure, static)
Humidity Range 20% RH~95%RH
Temperature Range during Humidity Test 20°C~85°C
Humidity Deviation (Humidity ≥75%RH) +2~-3%RH (Humidity <75%RH) ±5%RH
Duct Pressure Range Normal pressure~40kPa (approximately equivalent to altitude of 6100m)
Duct Pressure Accuracy ±2KPa (with load, after 3 minutes of dynamic operation, maximum ≤±5KPa within 3 minutes)
Duct Pressure Reduction Rate Normal pressure~40kPa ≤10min
Duct Pressure Recovery Rate 40kPa~normal pressure ≤10min
Duct Pressure Deviation ≤±2KPa