WNS Series Condensing Gas (Oil) Steam Boiler

Negotiable
China
House, South of Gongye North Road, Hejiadian, Liaolan Town, Pingdu City, Qingdao City, Shandong Province, East of Planned Industrial Park Road
13964251037
Online Contact
Favorite

Product Introduction

Product Description:

1. Horizontal fully wet-back structure, compact overall layout, elegant and aesthetically pleasing.

2. External integrated finned tube economizer and independent vertical condenser, compact structure for easy maintenance.

3. Rational heating surface structural design effectively controls flue gas resistance.

4. Variable frequency feed water and control technology ensures the condensation rate of water vapor in flue gas.

5. The condenser is made of special steel resistant to low-temperature sulfuric acid dew point corrosion, greatly extending service life.

6. Programmable Logic Controller (PLC) combined with touch screen, supplemented by buttons, enables a dual intelligent control system with both manual and automatic modes.

7. Comprehensive safety interlock protection functions ensure safe and efficient boiler operation.

8. Multiple boilers can be networked without a master control console, automatically selecting the number of operating boilers and distributing the load among them.

Product Parameters

Technical Parameter Table for WNS Series Condensing Gas (Oil) Steam Boiler


Boiler Model
WNS1-0.7-QY
WNS1-1.0-QY
WNS2-1.0-QY
WNS2-1.25-QY
WNS3-1.0-QY
WNS3-1.25-QY
WNS4-1.25-QY
WNS4-1.6-QY
WNS6-1.25-QY
WNS6-1.6-QY
WNS8-1.25-QY
WNS8-1.6-QY
WNS10-1.25-QY
WNS10-1.6-QY
WNS15-1.25-0Y
WNS15-1.6-QY
WNS20-1.25-QY
WNS20-1.26-QY
Rated Evaporation Capacity (t/h) 1 2 3 4 6 8 10 15 20
Rated Working Pressure (MPa) 0.7/1.0 1.0/1.25 1.0/1.25 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6
Rated Steam Temperature (℃) 170/184 184/194 184/194 194/204 194/204 194/204 194/204 194/204 194/204
Feed Water Temperature (℃) 20 20 20 20 20 20 20 20 20
Heating Surface Area
(m²)
Boiler Body

Condenser
24.06

15.4
58.15

29.64
89.99

45.60
112.59

53.54
181.17

78.25
190.77

108.50
229.95

165.30
346.20

216.20
467.60

360.30
Thermal Efficiency (%) >98 >98 >98 >98 >98 >98 >98 >98 >98

Applicable Fuels: Natural gas, biogas, coke oven gas, light oil, methanol, biodiesel, etc.

Combustion Equipment: Burner
Total Motor Power (kW) 3.6 7.0 10.5 13.0 19.5 29.5 33 60 90.5
Feed Water Pump Model JGGC2-8
×16
JGGC2.4-8
×18
JGGC4-8
×22
JGGC4.8-8
×22
JGGC6-8
×19
JGGC9-15
×10
JGGC12.5-15
×11
JGGC16-15
×12
JGGC25-35
×5
Fuel Consumption Natural Gas (Nm³/h)

Light Oil (kg/h)
72

66
144

113
216

196
288

266
432

399
576

532
720

660
1080

997
1440

1204
Maximum Transport Weight (t) 4.0 8.5 8.9 11.3 19.5 22.6 25.8 37.4 46
Maximum Transport Dimensions
L×W×H (m)
3.25×1.8
×2.1
4.4×2.1
×2.46
4.6×2.31
×2.62
4.70×2.48
×2.85
5.93×2.6
×3.02
5.85×2.8
×3.1
7.65×2.81
×3.1
6.95×3.1
×3.6
8.3×3.4
×4.02

Technical Parameter Table for WNS Series Condensing Gas (Oil) Hot Water Boiler

Boiler Model WNS0.7-0.7
/95/70-QY
WNS1.4-0.7
/95/70-QY
WNS2.8-0.7
/95/70-QY
WNS4.2-1.0
/115/70-QY
WNS5.6-1.0
/115/70-QY
WNS7-1.0
/115/70-QY
WNS10.5-1.25
/115/70-QY
WNS14-1.25
/115/70-QY
Rated Thermal Power (MW) 0.7 1.4 2.8 4.2 5.6 7.0 10.5 14
Rated Working Pressure (MPa) 0.7 0.7 0.7 1.0 1.0 1.0 1.25 1.25
Rated Outlet Water Temperature (℃) 95 95 95 115 115 115 115 115
Rated Inlet Water Temperature (℃) 70 70 70 70 70 70 70 70
Heating Surface Area
(m²)
Boiler Body

Condenser
26

14
58.8

24.7
112.59

45.6
180.91

78.25
189.87

108.5
205.57

148.8
346.19

192.1
127.68

330.3
Thermal Efficiency (%) >98 >98 >98 >98 >98 >98 >98 >98
Applicable Fuels: Natural gas, biogas, coke oven gas, light oil, methanol, biodiesel, etc.
Combustion Equipment: Burner
Fuel Consumption Natural Gas (Nm³/h)

Light Oil (kg/h)
72

66
144

133
288

266
432

397
576

530
720

656
1080

996
1440

1327
Maximum Transport Weight (t) 4.0 8.3 13.3 19.5 22.6 25.8 33 46
Maximum Transport Dimensions
L×W×H (m)
3.25×1.8
×2.1
4.4×2.1
×2.46
4.7×2.48
×2.85
6.2×2.8
×3.1
7.04×2.87
×3.1
7.3×2.88
×3.16
8×3.37
×3.57
7.77×3.7
×3.99