Groundbreaking for the €60 Million Data Center at the University of Augsburg, Germany
en.Wedoany.com Reported - On November 17, the groundbreaking ceremony was held for the new data center of the University of Augsburg, Germany. The project is funded by the Bavarian State Government with an investment of approximately €60 million. Located at the boundary between the university's main campus and the Augsburg Innovation Park, it is planned as a two-story building with an area of more than 4,000 square meters. Construction began in September this year, excavation of the foundation pit has now been completed, and the project is scheduled for completion in 2029.

The project is being implemented by the Augsburg State Building Authority on behalf of the Bavarian State Government, with Drees & Sommer responsible for overall planning, ZECH Bau as general contractor for detailed design and construction, and Berlin-based KEC Architekten responsible for the architectural design.
The new data center will be equipped with server rooms, network and supporting infrastructure, high-performance computing equipment for research, a consultation center, multimedia rooms, student workspaces, and operations and maintenance office facilities, providing IT services for the university's main campus and the medical school campus.
After the new data center is completed, the university will renovate the existing data center built in 1989 and, through redundant ring-topology IT infrastructure links, connect the new and old data centers and a third site into a multi-node disaster recovery system to ensure the operational continuity of information systems for teaching, research, and administration.
The data center areas will use precast reinforced concrete components, while the student study and office areas will use hybrid timber-concrete structures. The building exterior will feature a ventilated façade and vertical shading elements, along with a green roof, partial green façade, and courtyard landscaping.
The project will include a photovoltaic system with an expected annual power generation of approximately 140 MWh, direct cooling via heat exchangers using groundwater from wells, and a water-to-water heat pump to recover waste heat from the data center to heat the office areas. A ventilation exhaust air heat recovery system will preheat the fresh air supply for the office areas. According to the design scheme, the building's primary energy demand will be approximately 45% lower than the requirements stipulated by Germany's Building Energy Act (GEG).
Related Products

Mine Explosion-proof and Intrinsically Safe Industrial Ethernet Ring Network (10 Gigabit/Gigabit)
Chongqing Mas Sci&Tech Co., Ltd.
Flat Portable Satellite Terminal 0.35m Aperture Manual Portable Terminal
China Starwin Science & Technology Co., Ltd.

JiuTian OneSky Pilot—Intelligent Management And Service Platform
China Times Prospect Science & Technology Co., Ltd.
One-Stop Steward Service for the Entire Logistics System Integration Chain
Zhongding Intelligent (Wuxi) Technology Co., Ltd.
Industrial and Commercial Point-Type Gas Detector
Jinan Benan Technology Development Co., Ltd.
Automatic Aiming Laser Remote Obstacle Removal Robot
Pinggao Group Weihai High-Voltage Apparatus Co., Ltd.













