Product Introduction

Product Features:

Advanced air duct design utilizing CFD flow field simulation technology to optimize internal airflow, ensuring temperature uniformity and stability while effectively controlling evaporator frosting

Excellent energy-saving technology with a control system that uses PWM cold control mode—heating without cooling and cooling without heating—achieving over 40% energy savings under steady-state operation

Versatile structural options: the full range of three-integrated products offers three structure types—self-lifting platform, scissor-lift hydraulic table, and gantry frame (primarily for large-scale systems)—to suit on-site conditions and chamber volume requirements

Product Parameters

Model

JC500CVH

JC1000CVH

JC1700CVH

JC3400CVH

Nominal internal volume (L)

500L

1000L

1700L

3400L

Performance parameters

Temperature range

-70 ℃ ~ +150 ℃

Humidity range

20% to 98% R.H

Temperature fluctuation

≤ ± 0.5

Temperature uniformity

≤ ± 2 ℃

Temperature deviation

≤ ± 2 ℃

Humidity deviation

-3 ~ + 2% R.H. (above 75% R.H.), ± 5% R.H. (below 75% R.H.)

Standard load (kg aluminum ingot)

20

40

80

150

Heating rate (average/linear)

3℃/min

Cooling rate (average/linear)

1℃/min

Remarks

The above indicators are measured under no-load and ambient temperature of 20±2 ℃ (according to GB/T5170.2-2017)

Internal dimensions (mm)

D

800

1000

1200

1500

W

800

1000

1200

1500

H

800

1000

1200

1500

Matching vibration table table size mm

Water platform ≤ 500 × 500

Vertical platform ≤ φ500

Water platform ≤ 700 × 700

Vertical platform ≤ φ700

Water platform ≤ 900 × 900

Vertical platform ≤ φ900

Water platform ≤ 1200 × 1200

Vertical platform ≤ φ1200

Cooling mode

Water cooling

Power supply form

380V ± 10%/50HZ ± 1, three-phase five-wire system (3P + N + G)

Meet the test method

GB2423.1-2008, GB2423.2-2008, GB2423.3-2008; GB2423.4-2008, GJB150.3-2009, GJB150.4-2009, GJB150.9-2009

Safety protection function

Power supply undervoltage, overvoltage, phase loss, phase sequence error protection; Triple overtemperature protection; Heater short circuit protection, refrigerator overpressure/overload/oil shortage protection; Humidifier fault protection; Blower motor overload/overheat protection; Control board overcurrent protection, leakage protection; Cooling water shortage protection, etc.