Main Technical Parameters
(1)Applicable diameter range for steel wire rope/continuous oil pipe: Φ10-120mm
(2)Metal cross-sectional area (LMA) loss rate detection error: < ±1%
(3)Damage point positioning accuracy: ≥99%
(4)Monitoring speed: 0-20m/s
(5)Passability: Unaffected by surface burrs, oil contamination, or deformation
(6)Distance between sensor and wire rope: 10–30mm
(7)Measured wire rope/continuous oil pipe swing threshold: <10mm
(8)Weak magnetic sensor sensitivity: 12V/mT
(9)Machine vision recognition accuracy: 0.2mm × 0.2mm
(10)Electromagnetic induction signal-to-noise ratio: S/N > 85dB
(11)Maximum sampling accuracy: 2048 times/m
(12)System operating voltage: AC220V/127V ±10%/50Hz
(13)System communication network: Wireless / wired industrial Ethernet
(14)Docking communication protocol: TCP/IP, Modbus
(15)Dustproof & waterproof rating: IP67
(16)Operating environment: -20℃~+60℃ / RH ≤95%
(17)Continuous operating time: ≥168h
(18)Equipment service life: ≥10 years
Detection Rate
Severe damage: Metal cross-sectional area loss rate 8%–10%, real-time detection rate 100%
Heavy damage: Metal cross-sectional area loss rate 6%–8%, real-time detection rate 100%
Moderate damage: Metal cross-sectional area loss rate 4%–6%, real-time detection rate 100%
Mild damage: Metal cross-sectional area loss rate 2%–4%, real-time detection rate >99%
Minor defect: Metal cross-sectional area loss rate = 2%, real-time detection rate >95%
Metal cross-sectional area loss rate >1%, real-time detection rate ≥80%
Repeatability
Severe damage: 100%, damage detection waveform basically fits
Heavy damage: 100%, damage detection waveform basically fits
Moderate damage: >99%, damage detection waveform basically fits
Mild damage: >95%, damage detection waveform basically fits
Minor damage: >80%, damage detection waveform basically fits
Accuracy
Steel wire rope/continuous oil pipe metal cross-sectional area (LMA) loss rate detection error: < ±1%
Twisted distance wire break number error: <1 wire*
Steel wire rope/continuous oil pipe diameter measurement error: ±1%*
Steel wire rope/continuous oil pipe length measurement error: <0.2%
Damage point positioning accuracy: ≥99%
Note: *Partial configuration includes AI machine vision recognition system