The VDS-12/40.5 series vacuum circuit breaker is a new type of circuit breaker independently developed by Shanghai Pinggao Tianling Switchgear Co., Ltd. This product is suitable for indoor switchgear with rated voltage 12kV-40.5kV and three-phase AC 50Hz, serving as a control and protection unit for high-voltage electrical equipment. It is widely used in power plants, power grids, petrochemical, metallurgy, coal mines, and urban infrastructure construction projects such as subways, airports, and buildings. The circuit breaker adopts a modular spring operating mechanism, which is simple and mature with reliable and convenient operation. It can perform frequent operations or multiple short-circuit current interruptions within the working current range. The VDS series vacuum circuit breaker can be used alone or in N2X-12/24 and N2S/N2N-40.5 series gas insulated metal-enclosed switchgear, and can be interchanged with similar foreign products.
VDS-12/40.5 Series Vacuum Circuit Breaker
VDS-12 Vacuum Circuit Breaker Technical Parameters
|
Item |
Unit |
Parameter |
||||
|
Rated Voltage |
kV |
12 |
||||
|
Rated Insulation Level |
Short-Time Power Frequency Withstand Voltage / Open Contacts |
To Earth and Between Phases: 42; Open Contacts: 48 |
||||
|
Lightning Impulse Withstand Voltage |
To Earth and Between Phases: 75; Open Contacts: 85 |
|||||
|
Rated Frequency |
Hz |
50 |
||||
|
Rated Current |
A |
630、1250、2000、2500、3150 |
3150、4000 |
|||
|
Rated Short-Circuit Breaking Current |
kA |
20 |
25 |
31.5 |
40 |
|
|
Rated Short-Time Withstand Current |
20 |
25 |
31.5 |
40 |
||
|
Rated Short-Circuit Making Current (Peak) |
50 |
63 |
80 |
100 |
||
|
Rated Peak Withstand Current |
50 |
63 |
80 |
100 |
||
|
Rated Phase-to-Phase Short-Circuit Breaking Current |
27.4 |
|||||
|
Rated Out-of-Step Breaking Current |
/ |
|||||
|
Rated Out-of-Step Making Current |
/ |
|||||
|
Rated Short-Circuit Duration |
s |
4 |
||||
|
Rated Single / Back-to-Back Capacitor Bank Switching Current |
A |
630/400 |
||||
VDS-40.5 Vacuum Circuit Breaker Technical Parameters
|
Item |
Unit |
Parameter |
||
|
Rated Voltage |
kV |
40.5 |
||
|
Rated Frequency |
Hz |
50/60 |
||
|
Rated Current |
A |
1250 |
2500 |
|
|
Rated Short-Time Power Frequency |
Between Phases and to Earth |
95 |
||
|
Withstand Voltage (1min, RMS) |
Open Contacts |
kV |
118 |
|
|
Auxiliary and Control Circuits |
2 |
|||
|
Rated Lightning Impulse |
Between Phases and to Earth |
kV |
185 |
|
|
Open Contacts |
215 |
|||
|
Rated Short-Time Withstand Current |
kA |
25/31.5 |
||
|
Partial Discharge Level |
pC |
≤10 |
||
|
Rated Peak Withstand Current |
kA |
63/80 |
||
|
Rated Short-Circuit Duration |
s |
4 |
||
|
Rated Short-Circuit Breaking Current |
kA |
25/31.5 |
||
|
Rated Short-Circuit Making Current |
kA |
63/80 |
||
|
Rated Operation Sequence |
O-0.3s-CO-180s-CO |
|||
|
Rated Short-Circuit Breaking Current Operations |
Times |
30(E2) |
||
|
Rated Phase-to-Phase Earth Fault Breaking Current |
kA |
21.8/27.4 |
||
|
Rated Out-of-Step Breaking Current |
kA |
6.3/7.9 |
||
|
Rated Cable Charging Breaking Current |
A |
50(C2) |
||
|
Rated Operating Voltage of Operating Circuit |
V |
DC/AC220 |
||
|
Rated Supply Voltage of Energy Storage Motor |
V |
DC/AC220 |
||
|
Energy Storage Time |
s |
≤15 |
||
|
Closing/Opening Trip Coil Working Current |
A |
1.3 |
||
|
Energy Storage Motor Power |
W |
120 |
||
|
Main Circuit Resistance |
μΩ |
≤60 |
≤45 |
|
|
Mechanical Operations |
Times |
10000(M2) |
||