Glass insulators are the core insulating components of transmission lines, made of high-strength tempered glass, combining excellent electrical insulation and mechanical load-bearing performance. Their smooth surface has strong self-cleaning properties, outstanding pollution flashover resistance and aging resistance. Defects can be visually detected through self-explosion during operation, facilitating rapid maintenance. Suitable for AC/DC, UHV/EHV transmission lines, widely used in State Grid, China Southern Power Grid and overseas power grid projects, with significant advantages such as long service life, low maintenance cost and high safety and reliability.

Our company's products adopt scientific design and refined manufacturing processes, establishing a full-process closed-loop quality control system. At the raw material end, high-quality suppliers are strictly selected, and all raw and auxiliary materials and metal fittings undergo strict incoming inspection before being put into storage. Semi-finished glass parts undergo batching, melting, forming, tempering, secondary cold and hot shock, homogenization treatment and full appearance inspection before storage; to completely eliminate internal stress hazards, all semi-finished glass parts must undergo a 3-month static stress relief period before entering the final gluing and curing process. The final finished products are packaged and shipped after passing full outgoing inspection.

Our company's product system is complete, covering five major AC series of standard type, pollution-resistant type, aerodynamic type, double umbrella/triple umbrella type, and ground wire type, as well as DC dedicated series. Voltage levels fully cover AC 10kV~1000kV and DC ±100kV~±1100kV, with mechanical load ranges from 40kN~840kN, meeting the construction needs of transmission lines under different voltage levels and environmental conditions.

Product implementation standard system: GB, IEC, ANSI, BS, CSA, AS.

Product Parameters
Jinlihua Model LXHP4-70 LXHP6-70 LXHP4-100 LXHP6-100 LXHP4-120 LXHP6-120 LXHP3-160 LXHP6-160
Nominal Diameter(mm) 280 320 280 320 280 320 280 320
Nominal Structure Height(mm) 146 146 146 146 146 146 155 155
Nominal Creepage Distance(mm) 450 550 450 550 450 550 450 550
Standard Coupling Marking(mm) 16 16 16 16 16 16 20 20
Mechanical Failing Load(kN) 70 70 100 100 120 120 160 160
Individual Tensile Failing Load Test(kN) 35 35 50 50 60 60 80 80
Power Frequency Wet Withstand Voltage(kV) 50 55 50 55 50 55 50 55
Lightning Impulse Withstand Voltage(kV) 125 140 125 140 125 140 125 140
Power Frequency Puncture Withstand Voltage(kV) 130 130 130 130 130 130 130 130
Radio Interference Voltage(μV) ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50
Visible Corona Test Foot/Cap(kV) 18/22 18/22 18/22 18/22 18/22 18/22 18/22 18/22
Power Frequency Arc Test 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA
Insulator Unit Net Weight(kg) 5.8 9.2 5.8 9.2 5.8 9.2 7.1 9.5

 

Jinlihua Model LXHP3-210 LXHP2-300 LXHP3-300 LXHP-300 LXP2-420 LXHP-550
Nominal Diameter(mm) 320 340 390 390 380 400
Nominal Structure Height(mm) 170 195 195 195 205 240
Nominal Creepage Distance(mm) 550 550 635 690 620 710
Standard Coupling Marking(mm) 20 24 24 24 28 32
Mechanical Failing Load(kN) 210 300 300 300 420 550
Individual Tensile Failing Load Test(kN) 105 150 150 150 200 275
Power Frequency Wet Withstand Voltage(kV) 55 55 55 55 55 55
Lightning Impulse Withstand Voltage(kV) 140 140 155 155 125 140
Power Frequency Puncture Withstand Voltage(kV) 130 130 130 130 130 130
Radio Interference Voltage(μV) ≤50 ≤50 ≤50 ≤50 ≤50 ≤50
Visible Corona Test Foot/Cap(kV) 18/22 18/22 18/22 18/22 18/22 18/22
Power Frequency Arc Test 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA 0.12s, 20kA
Insulator Unit Net Weight(kg) 10.2 12.5 14.5 15.5 17.2 23