Scope of application:
Curtain wall insulation system and building filling system.
Scope of application:
Curtain wall insulation system and building filling system.
|
Technical specifications |
|||||
|
Serial Number |
Inspection (verification) items |
National Standards |
Measured value |
||
|
1200×600×50(mm) 80kg/m³ |
1200×600×100(mm) 100kg/m³ |
||||
|
1 |
Acidity coefficient |
≥ 1.6 |
≥ 2.0 |
≥ 2.0 |
|
|
2 |
Thermal conductivity (average temperature 25 ℃)W/(m.K) |
≤ 0.040 |
≤ 0.038 |
≤ 0.038 |
|
|
3 |
Combustion performance (GB 8624) |
Grade A |
A1 |
A1 |
|
|
4 |
Hydrophobic rate % |
≥ 98.0 |
≥ 99.0 |
≥ 99.0 |
|
|
5 |
Water absorption % |
- |
≤ 5 |
≤ 5 |
|
|
6 |
Moisture absorption rate of mass % |
≤ 0.5 |
≤ 0.5 |
≤ 0.5 |
|
|
7 |
Content of slag ball (particle size greater than 0.25mm)% |
≤ 7 |
≤ 5 |
≤ 5 |
|
|
8 |
Average fiber diameter μm |
≤ 6.0 |
≤ 6.0 |
≤ 6.0 |
|
|
9 |
Radioactive Element |
Internal exposure index |
≤ 1 |
≤ 1 |
≤ 1 |
|
External exposure index |
≤ 1 |
≤ 1 |
≤ 1 |
||