Product specifications table
|
|
Model
|
DEP Series
|
|
Input
|
Mains voltage
|
AC187 ~ 242V/AC310 ~ 450V
|
|
Mains frequency
|
50Hz ± 10%
|
|
Input current
|
The maximum input current is 1.2 times the rated input current
|
|
Two-way mutual investment
|
Optional
|
|
Static switch
|
Optional
|
|
Charger
|
Bridge rectifier
|
Three-phase 6-pulse controlled rectifier
|
|
Circuit structure and control strategy
|
DC output voltage closed-loop control (PID), Rectifier output current, Battery charging current cut-off negative feedback regulation.
|
|
Rated input voltage (VAC)
|
380V/400V/415V-25%+ 25%, three-phase three-wire or three-phase four-wire
|
|
Input frequency
|
50/60Hz ± 10%
|
|
Charging voltage
|
According to the battery capacity can be set
|
|
Charging current
|
According to the battery capacity can be set
|
|
Battery
|
Maintenance-free sealed battery
|
|
Battery voltage
|
110VDC/220VDC/360VC/480V/492VDC
|
|
Standby time
|
30 minutes (can be configured according to user requirements)
|
|
Normal state output
|
Output voltage
|
Consistent with the mains
|
|
Output frequency
|
Consistent with the mains
|
|
Efficiency
|
≥ 99%
|
|
Emergency status state output
|
Output voltage
|
Single phase 220V ± 1%, three phase 380V ± 1%
|
|
Output frequency
|
50/60Hz ± 0.1Hz
|
|
Rated output power factor
|
0.8
|
|
100% Load regulation rate
|
<± 1%
|
|
Voltage total harmonic distortion (rated load)
|
<3%
|
|
Dynamic voltage transients and recovery time
|
0~5 ms, dynamic voltage transient ≤ ± 30%;5~20 ms, dynamic voltage transient to ≤14%;20~100 ms, dynamic voltage transient drop to ≤ 5%;(GB7260.3-5.3.1The first class dynamic performance is 20~100 ms, and the dynamic voltage transient drops to ≤ ± 10%GB7260.3-6.3.7)
|
|
Efficiency
|
> 95% (at rated load)
|
|
Number of output splits
|
4-Way (can be expanded according to user requirements)
|
|
Output shunt characteristics
|
Continuous type, non-continuous type, fire linkage type
|
|
Overload characteristics
|
Normal output at 120%; ≥ 30 s at 150%
|
|
Conversion time
|
Power supply from grid to Emergency State is 0 ms
|
|
0 ms for switching from emergency power supply to grid power supply
|
|
Display
|
LED+ LCD
|
|
Operating ambient temperature
|
-30 ℃ ~ +55 ℃
|
|
Relative humidity
|
0-90%
|
|
Altitude
|
≤ 2500 m; When 2500~5000 m, system ventilation device shall be added or derated.
|
|
Adapt to load
|
Various lighting loads or other capacitive or inductive motor loads
|
|
Noise
|
There is no noise when the power grid has electricity, and the noise is less than 60dB in case of emergency power supply
|
|
Dimensions/Weight
|
See Size/Weight Schedule
|
|
Door opening mode
|
Main cabinet: front door; Battery cabinet: front and rear doors
|
|
Access line mode
|
Bottom inlet and outlet line (standard type) according to user requirements
|