- When configuring subsystem monitoring, it can be redundantly configured with subsystem monitoring.
- Independent fullspecificationmonitoring for substations at all voltage levels from 10-750kV without subsystem monitoring.
- Modular configuration technology.
- Customized human-machine interface fully corresponding to system configuration.
- Display interface size options available based on substation level.
- High-resolution, high-brightness true color industrial-grade TFT touchscreen.
- Equipped with multiple communication interfaces: USB, Ethernet, RS232/485, and CAN.
- Underlying CAN bus communication.
HRE series DC power supply
Technical specifications
|
HRE-M-10 system monitoring |
|
|
Supply voltage |
DC24V |
|
Supply current |
≤ 1.5A |
|
Product Configuration |
Main frequency 400MHz |
|
RAM 64M |
|
|
RAM128M |
|
|
Screen 10.4 inches |
|
|
Interface |
2-way RS485 interface, 1-way CAN interface, 1 Channel 100m Ethernet port, 1 channel USB main port, 1 channel USB slave port |
|
Product size |
315 × 239 × 56mm |
|
HRE-ATS-10 incoming line monitoring unit |
|
|
Supply voltage |
DC80-320V AC80-264V |
|
Supply current |
≤ 0.1A |
|
Detection amount |
Two incoming line voltage, bus voltage and current, zero sequence current, 32-channel switching inputs, 21-channel relay outputs, 8-channel dial switch, electric energy meter interface |
|
Communication Port |
2-way RS485 interface |
|
1 CAN bus interface |
|
|
Product size |
424 × 200 × 55mm |
|
HRE-K-10 feeder monitoring unit |
|
|
Supply voltage |
DC80-320V AC80-264V |
|
Supply current |
≤ 0.1A |
|
Detection amount |
32-channel switch input, 16-channel analog input, 8-channel dial Switch |
|
Communication Port |
1-way RS485 interface |
|
1 CAN bus interface |
|
|
Product size |
299 × 138 × 55mm |
|
HRE-DC-1 0 DC monitoring unit |
|
|
Supply voltage |
DC80-320V AC80-264V |
|
Detection amount |
8-channel switch input, 8-channel relay output, 8-channel analog input, 8-channel dial switch, 1-channel temperature signal |
|
Communication Port |
1-channel RS485 interface |
|
1-channel CAN bus interface |
|
|
Technical features |
Can detect 8-channel switch state, Can control 8-channel relay contact output |
|
It can detect the power of bus joint, control bus and battery.Voltage current, can detect the bus insulation state |
|
|
Can detect all the channel temperature state |
|
|
R22010F/20F/30F rectifier module |
||||
|
Technical specifications |
Voltage stabilization accuracy |
≤ 0.5% |
Steady flow accuracy |
≤ 0.5% |
|
Conversion efficiency |
≥ 94% |
Audible noise |
≤ 55db |
|
|
Ripple coefficient |
≤ 0.1% |
Homogeneous flow |
≤ 3% |
|
|
Features |
CAN bus communication technology, full soft switching technology |
|||
|
Technical features |
Input |
380V ± 15%,50Hz ± 10% |
||
|
Output |
10A-30A/230V(180V-286V) |
|||
|
Cooling mode |
Intelligent air cooling |
|||