ZN85-40.5 Drawout Type Indoor High-voltage Vacuum Circuit Breaker
Negotiable
China
No.3, 22nd Street, Eastern New District, Wenling City, Taizhou City, Zhejiang Province
010-83910265
Online Contact
Favorite
Product Introduction

The ZN85-40.5 drawout type indoor high-voltage vacuum circuit breaker is designed for three-phase AC power systems rated at 40.5kV and 50Hz. It is widely used in industrial and mining enterprises, power plants, and substations for frequent switching operations, serving as a control and protection device. The product's technical performance complies with GB1984-2014 "High-voltage Alternating Current Circuit Breakers," JB3855-1996 "3.6-40.5kV Indoor AC High-voltage Vacuum Circuit Breakers," and IEC standards.

This product adopts an integrated and modular vertical layout structure. The three-phase vacuum interrupter is housed in an insulated cylinder mounted on the upper part of the frame, while the spring operating mechanism is installed in the lower cabinet. The overall design is simple, compact, and easy to maintain, providing reliable breaking and closing capabilities for load currents, overload currents, and short-circuit currents in power systems.

Product Parameters

No.

Item

Unit

Value

1

Rated voltage

kV

40.5

2

Rated Insulation Level

1-minute power frequency withstand voltage (phase-to-phase, phase-to-earth, across isolating distance)

kV

95

Lightning impulse withstand voltage (phase-to-phase, phase-to-earth, across isolating distance)

kV

185

3

Rated frequency

Hz

50

4

Rated current

A

1250

1600

2000

5

Rated short time withstand current (4s)

kA

25

31.5

6

Rated peak withstand current

kA

60

80

7

Rated short circuit breaking current

kA

25

31.5

8

Rated short circuit making current

kA

63

80

9

Rated operating sequence

 

O-0.3s-CO-180s-CO

10

Rated short-circuit breaking current breaking times

Times

20

11

Rated capacitor bank breaking current

A

630

12

Rated control voltage (DC or AC)

V

220;110

13

Mechanical life

Times

10000

Mechanical Characteristics Parameter Table After Circuit Breaker Assembly and Adjustment

No.

Item

Unit

Value

1

Contact Opening Distance

mm

20±2

2

Contact Stroke

mm

4±1

3

Average Closing Speed

m/s

0.8±0.2

4

Average Opening Speed

m/s

1.8±0.2

5

Opening Time (Rated Voltage)

ms

≤50

6

Closing Time (Rated Voltage)

ms

≤100

7

Contact Closing Bounce Time

ms

≤3

8

Three-phase Closing Asynchrony

ms

≤2

9

Cumulative Allowable Wear Thickness of Moving and Static Contacts

mm

3

10

Main Circuit Resistance

μΩ

≤70