ZW32-12 Outdoor Column Vacuum Circuit Breaker

Negotiable
China
No.868 Jiahang Road, Jiading District, Shanghai
+86 21 69900817
Online Contact
Favorite
Product Introduction

The ZW32-12 outdoor column vacuum circuit breaker is an outdoor distribution device with a rated voltage of 12kV and three-phase AC 50Hz. It is mainly used to break/close load current, overload current and short-circuit current in power systems. It is suitable for protection and control in substations and industrial and mining enterprise distribution systems, and is more suitable for rural power grids and places with frequent operations.

Performance Features:

·The circuit breaker adopts a three-phase pillar structure. The pole is equipped with phase voltage, zero-sequence voltage, phase current, and zero-sequence current sensors, as well as built-in energy-taking capacitors, which can be flexibly arranged on the incoming or outgoing line side according to different customer needs. It has low power consumption and high accuracy. The sensor parameters meet the group standard T/CES018-2018 "Technical Conditions for 10kV and 20kV AC Sensors in Distribution Networks".

·An AC-DC module is installed inside the box, which can output a power supply with a voltage of 28V and a maximum power of 60W to meet the power consumption needs of intelligent terminals. It no longer relies on external PT power, reducing safety hazards. The circuit breaker has good sealing effect and can meet IP65/IP67 standards. It is a new generation of high-precision maintenance-free product that meets the latest requirements of the State Grid.

Product Parameters

Item

Unit

Parameter

Rated Voltage

kV

12

Rated Frequency

Hz

50

Rated Current

A

630

Rated Short-Time Power Frequency Withstand Voltage (1min, RMS)

Dry Test (Between Phases, Phase to Earth / Open Contacts)

kV

42/48

Wet Test (Between Phases, Phase to Earth, Open Contacts)

42/48

Rated Lightning Impulse Withstand Voltage (Peak) (Between Phases, Phase to Earth / Open Contacts)

kV

75/85

Rated Short-Time Withstand Current

kA

20

Rated Peak Withstand Current

kA

50

Rated Short-Circuit Duration

S

4

Rated Short-Circuit Breaking Current (RMS)

kA

20

Rated Short-Circuit Making Current (Peak)

kA

50

Rated Operation Sequence

 

O-0.3s-CO-180s-CO

Rated Short-Circuit Breaking Current Breaking Operations

Times

30

Rated Phase-to-Phase Earth Fault Breaking Current

kA

17.3

Rated Cable Charging Breaking Current

A

25

Allowable Contact Wear Thickness

mm

≤3

Operating Mechanism Voltage

V

AC220

Main Circuit Resistance

μΩ

≤80

Mechanical Life

 

Times

10000