Product Introduction
- Performs automatic or single-step manual calibration of basic error, creep, start-up, and standard deviation for single or three-phase energy meters in accordance with relevant energy meter calibration regulations.
- Capable of conducting tests for changes caused by influencing factors such as voltage, frequency, and harmonics.
- Can simultaneously output highly stable and accurate three-phase voltage, current, phase, and other parameters, with the flexibility to independently adjust each phase.
Technical Parameters
- Outputs standard AC electrical parameters such as voltage, current, phase, and power.
- Maximum voltage output: 456V; maximum current output: 120A.
- Strong load capacity, with maximum output of 50VA per phase for voltage and 100 VA per phase for current.
- Output adopts multi-stage closed-loop control technology and multi-stage overload detection technology to ensure long-term stable and reliable output.
- Equipped with a large-size LCD screen, with human-machine interaction via full touch control.
- Built-in large-capacity FLASH ROM for storing and querying calibration data.