The VXZ intelligent natural gas inner cone flowmeter is a new type of intelligent gas flowmeter integrating high-precision differential pressure transmitter, pressure transmitter, temperature sensor, intelligent totalizer, and inner cone, specially designed for natural gas and compressed air flow measurement.
Main Features
- a) Self-rectifying function, no need for very long straight pipe sections: upstream ≤3D, downstream ≤1D.
- b) Reynolds number range: 8×10³ ~ 1×10⁷, upper limit can be higher, lower limit can be lower.
- c) Wide turndown ratio of 10:1, can be higher.
- d) Dirt-resistant, self-cleaning, no wear, good stability, repeatability 0.1%.
- e) Uses new microprocessor and high-performance integrated chip, high computation accuracy, powerful overall functions, superior performance.
- f) With segmented flow coefficient correction function.
- g) With 4~20mA current output and pulse signal output.
- h) Uses RS-485 or RS-232 interface for networking with host computer. Can include GPRS wireless data transmission function.
- i) Totalizer circuit board has lightning protection function.
- j) Uses 128×63 graphic dot-matrix LCD to display cumulative flow (standard conditions), instantaneous flow (standard conditions), natural gas compressibility factor, density, pressure, differential pressure, temperature, current time and last power-down time, daily/monthly/annual report query.
- k) Automatic recovery function: In addition to software watchdog, hardware system also has watchdog. Power-on/off reset system ensures forced recovery of instrument operation in case of program error or unexpected crash.
- l) Power-down protection function: Instrument computation and user-set data will not be lost during power failure, saved for more than ten years.
- m) Automatic power switching function: This instrument also supports UPS power connection. When normal external power is available, UPS is in charging state; when external power suddenly fails, the instrument automatically switches to UPS power.
- n) This series of products adopts explosion-proof design, certified by the National Explosion-proof Safety Supervision and Inspection Station for Instrumentation (NEPSI), complies with national standards GB3836.1-2000, GB3836.2-2000, GB3836.3-2000, explosion-proof mark Exde II BT4, explosion-proof certificate No. GYB071045.
Main Technical Parameters
1 System uncertainty ±1.5%.
Includes temperature, pressure, differential pressure, supercompressibility factor, true relative density, flow totalizer section, inner cone throttling element section. Among them:
- a Pressure indication error: ±0.2% FS
- b Temperature indication error: ±0.1°C
- c Differential pressure indication error: ±0.2% FS
- d Flow totalizer accuracy: ±0.5% FS
- e Inner cone throttling element: ±0.5% FS
2 Standard condition
P=101.325KPa t=20°C
3 Operating conditions:
- a Ambient temperature: -20°C ~ 60°C
- b Medium temperature: -20°C ~ 135°C
- c Relative humidity: 5%~95%
- d Atmospheric pressure: 75KPa~106KPa
4 Electrical performance indicators
Operating power: +24VDC ±15% ripple ≤ ±5%
Overall power consumption: <1W
Output methods
- a. Uses RS485, RS232 interface, can directly network with host computer or secondary instrument, remotely display measured two-phase flow medium temperature, pressure, differential pressure, standard instantaneous flow, standard cumulative flow, holdup ratio, daily/monthly/annual reports, power-down records, and various set parameters.
- b. 4~20mA current signal output, corresponding to zero flow and maximum flow.
- c. Has frequency signal output proportional to standard volume flow, 0~1000HZ corresponding to minimum flow and maximum flow.
- d. Has calibration pulse output: one pulse output for every certain unit of standard volume metered by the flowmeter. (Note: Frequency signal and calibration pulse output signal can only be selected as one by software setting)
5 Real-time data storage function
For user data management needs, the flowmeter can store real-time data detected and calculated by the totalizer in real time.
6 Wireless data transmission function
The flowmeter can transmit real-time data to the host computer via GPRS system in SMS form, enabling automated production management.
7 Explosion-proof mark "Exde II BT4"