Technical parameters:
①It can be connected to 5 channels 4 ~ 20mA input signals (such as temperature, pressure, liquid level, etc.).
②With sound alarm function (such as circuit failure, etc.).
③The host backlight LCD can simultaneously display instantaneous flow, cumulative flow, flow rate, time, heat and other data.
④OCT signal: pulse signal of cumulative flow or frequency signal of instantaneous flow.
⑤Relay: can output nearly 20 kinds of source signals (such as no signal, reverse flow, etc.).
⑥Sound alarm: The buzzer can emit an alarm sound according to the setting.
⑦Signal input: can input 5 channels current signals (such as: temperature, pressure, liquid level and other signals) to achieve heat measurement or a dual-purpose machine.
⑧Automatically memorize the cumulative flow of the previous 64 days, the previous 64 months and the previous 5 years.
⑨Automatically memorizes the time and flow of the first 64 incoming calls and power-off times, and can be filled manually or automatically.
⑩Automatically record whether the working state of the flowmeter is normal and the number of abnormal states in the previous 64 days.
⑪Programmable batch (quantitative) controller.
⑫The measurement accuracy of standard pipe section φ 15 ~ φ 1000 is 0.5%.
⑬JT type pipe: Φ15, Φ20, Φ25, Φ32 and Φ40.
⑭Cable: In principle, the shorter, the better to reduce interference. It can be extended up to 300m, but if it needs to be longer, the cable should be thicker. Additionally, users should ensure that the cable does not run parallel to high-voltage cables.
⑮Pipeline conditions: pipe: carbon steel, stainless steel, cast iron, copper, PVC, aluminum, fiberglass, rigid metals, plastic, etc., with lining allowed.
⑰Straight pipe section: the upstream of the sensor installation point is ≥ 10D, the downstream is ≥ 5D, and the distance from the pump outlet is ≥ 30D (D refers to the pipe diameter).
Velocity range: 0 ~ ± 30 m/s.
Sensor technical parameter table
|
Sensor Name
|
Standard Type S1
|
Standard Type M1
|
Standard Type L1
|
|
Applicable pipe diameter
|
DN15 ~ DN100
|
DN50 ~ DN700
|
DN300 ~ DN6000
|
|
Material
|
ABS
|
|
Operating frequency
|
1MHz
|
|
Installation Method
|
V(N, W) method
|
V, Z method
|
Z method
|
|
Calibration
|
Whole machine pairing calibration
|
|
Applicable temperature
|
0 ℃ ~ 70 ℃
|
|
Protection level
|
IP65
|
|
Overall dimension
|
45*30*30
|
60*45*45
|
80*70*55
|
|
Mass (g/pair)
|
75
|
250
|
650
|
|
Media Type
|
Water, sea water, sewage, alcohol, all kinds of oil can conduct ultrasonic single, uniform, stable liquid
|
|
Medium turbidity
|
≤ 20000ppm and low bubble content
|
|
Applicable pipes
|
Carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastic and other uniform quality dense pipe, allowed to have lining
|
|
Pipe material
|
Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, bakelite, PTFE, etc.
|
|
Signal cable
|
Standard configuration: 5 meters * 2, optional 10 meters * 2 or 15 meters * 2
|
Selection table:
|
ZDL92
|
Type selection code
|
Description
|
|
Instrument grade
|
A
|
High precision, high stability
|
|
B
|
High stability
|
|
Sales mode
|
C, D, W (The selection personnel can be ignored)
|
|
Sensor
|
S1
|
Applicable to pipe diameter: φ15~φ100, fluid temperature ≤ 70 ℃
|
|
M1
|
Applicable to pipe diameter: φ50~φ700 fluid temperature ≤ 70 ℃
|
|
L1
|
Applicable to pipe diameter: φ300~φ6000 fluid temperature ≤ 70 ℃
|
|
T1
|
SPECIAL REQUIREMENTS
|
|
Cable length
|
User Fill Options
|
|
Power
|
D
|
DC8 ~ 36V
|
|
A
|
AC220V ± 15%
|
|
T2
|
SPECIAL REQUIREMENTS
|
|
Signal output
|
1
|
4-20mA Impedance 0-1K
|
|
2
|
0-20mA Impedance 0-1K
|
|
T3
|
SPECIAL REQUIREMENTS
|
|
Accuracy Class
|
1
|
0.1
|
|
5
|
0.5
|
|
T4
|
SPECIAL REQUIREMENTS
|
|
Data Interface
|
A
|
RS-232C
|
|
B
|
RS-485
|
|
T5
|
SPECIAL REQUIREMENTS
|
|
Selection example
|
ZDL921-CS15A15A
|