The ZDTC9101/9201 series conventional assembled thermocouples and resistance temperature detectors are traditional thermocouple and RTD products. They adopt a nationally standardized design and installation structure, making them highly versatile and convenient for users to replace original components. Since they still use conventional assembled cores, their vibration resistance, temperature measurement speed, and service life are not as good as those of armored products. Therefore, they are generally suitable for applications with less stringent product requirements and milder working conditions.
ZDTC9101/9201 series conventional assembled thermocouples and resistance temperature detectors
Product Introduction
Product Parameters
Main technical indicators:
|
Kind |
Indexing number |
Measurement range (℃) |
Accuracy Class |
Allowable Value |
Insulation resistance |
Placement depth |
Response time |
|
Thermocouple |
B |
0 ~ 1800 |
2 |
±0.25%t |
≥100MQ.m |
250~1000mm |
≤ 300s |
|
S |
0 ~ 1600 |
1 |
± 1.0 ℃ or ±{1+0.003(t-1100)}℃ |
≤ 300s |
|||
|
2 |
±1.5℃/±0.25%t |
||||||
|
K |
-40 ~ 1200 |
1 |
±1.5℃/0.4%t |
100~4000mm |
≤ 180s |
||
|
2 |
±2.5℃/±0.75%t |
||||||
|
E |
-40 ~ 900 |
1 |
± 1.5 ℃/±0.4%t |
≤ 180s |
|||
|
2 |
±2.5℃/±0.75%t |
||||||
|
J |
-40 ~ 750 |
1 |
±1.5℃/0.4%t |
≤ 90s |
|||
|
2 |
±2.5℃/±0.75%t |
||||||
|
T |
-40 ~ 350 |
1 |
±0.5℃/0.4%t |
≤ 90s |
|||
|
2 |
±1.0℃/±0.75%t |
||||||
|
Thermal resistance |
Pt100 |
-200~500 |
A |
±(0.15+0.002|t|) |
≥100MQ.m |
100~2500mm |
≤ 90s |
|
B |
±(0.30+0.005|t) |
||||||
|
Cu50 |
-50 ~ 150 |
- |
±(0.30+0.006|t|) |
≥50MQ.m |
≤ 90s |
||
|
Note: When thermal resistance products are placed in depth> 1000mm, it is recommended that users choose armored products. |
|||||||
Selection table:
|
ZDTC9101/ZDTC9201 |
Type selection code |
Description |
|
Instrument grade |
A B |
High precision, high stability |
|
High stability |
||
|
Structure grade |
A1 A3 C3 |
Full bore type |
|
Full cone pipe type |
||
|
Assembled core |
||
|
Form of junction box |
20 21 26 27 |
Wiring board type |
|
Outlet Splash-proof |
||
|
KNE type |
||
|
Small platinum rhodium special junction box |
||
|
Transformer output signal/corresponding temperature range |
W M/ V/ |
No transmission output |
|
Transmission output 4 ~ 20mA/temperature range |
||
|
transmission output 1~5V/temperature range |
||
|
Fixed installation form |
W F1 F2 G1 G2 L T1 |
No fixing device |
|
Fixed thread |
||
|
Movable thread |
||
|
Fixed flange |
||
|
Movable flange |
||
|
Right-angle type |
||
|
Special requirements |
||
|
Indexing number |
T J E K S B PT100 Cu50 |
T-indexing thermocouple |
|
J-indexing thermocouple |
||
|
E-indexing thermocouple |
||
|
K-indexing thermocouple |
||
|
S-indexing thermocouple |
||
|
B-indexing thermocouple |
||
|
PT100 Thermal Resistance |
||
|
Cu50 thermal resistance |
||
|
Number of components |
1 2 |
Single-element type |
|
Dual-element type |
||
|
Core type |
P |
Common assembly core |
|
Accuracy Class |
1 2 |
Industrial Class 1 |
|
Industrial Class 2 |
||
|
Material of protection tube |
B M C G Y L T2 |
1 Cr18Ni9Ti(0~1000 ℃) |
|
316L(0~1000 ℃) |
||
|
Cr25Ni20(0~1100 ℃) |
||
|
GH3030(0~1200 ℃) |
||
|
CT1(0~1600 ℃) |
||
|
CT2(0~1400 ℃) |
||
|
Special requirements |
||
|
Diameter of protection tube |
Two-digit numbers directly represent the actual diameter, for example, 16 represents φ16. |
|
|
Selection example |
ZDTC9201 A A320 W W k 1 P 1 B |
|
|
Ordering Method |
C D W The selection personnel can be ignored |
|
Other products from this supplier

ZDTC9105/9205 series on-site display type thermistor and thermocouple

ZDTC9103/9203 series corrosion-resistant thermocouples and resistance temperature detectors

ZDTC9104/9204 series independent armored thermocouples and resistance temperature detectors

ZDTC9102/9202 series explosion-proof thermocouples and resistance temperature detectors

ZDW96 series magnetic float level gauge

ZDW95 RF admittance level switch.

ZDW93 Integrated ultrasonic level transmitter.

ZDW921 Guided wave radar level transmitter.

ZDS4833 Remote differential pressure transmitter.

ZDS4733 Remote pressure transmitter (flat diaphragm type).

ZDS4633 level transmitter

ZDS4433 differential pressure transmitter
Related Products
Quick-Change Single-Seat Control Valve / Quick-Change High-Pressure Single-Seat Control Valve
Compact natural gas compressor for offshore platforms
Titanium/Steel Composite Tube Sheet
TOP-5879F1-A30 basic type (intelligent valve positioner)
Oil and gas chemical industry
Wide-channel Plate Heat Exchanger
Remotely Operated Vehicle — JT-5
Rotary Table Series
Multi-core control cable
2.7V 100000F (60wh) 60138 high-power energy storage power starting power supply (instantaneous high current), low-temperature discharge, long service life, 100000 times of use
Electric heat tracing instrument insulation box series