Technical parameters:
Measuring range: 2.5KPa ~ 500Kpa
Span ratio: 30:1
Power supply: 10.5V ~ 45V DC (Intrinsic safety type barrier power supply ≤ 30V DC)
Output: 4mA ~ 20mA DC and HART communication; PROFIBUS-PA communication
Ambient temperature:-40 ℃ ~ 85 ℃
Medium temperature:-40 ℃ ~ 100 ℃ (filled with silicone oil)
Accuracy: ≤(0.005r +0.071)%
Temperature drift: ≤(0.1r +0.2)%(-10 ℃ ~ 60 ℃)
≤(0.1r +0.15)%/10 ℃(-40 ℃ ~-10 ℃;60~85 ℃)
Static pressure impact: ≤ 0.15 r%/4Mpa (zero point); ≤ 0.2 %/4Mpa (range)
Long-term drift: ≤ 0.2 r%/5 years
Enclosure protection class: IP67
Explosion-proof grade: Ex dIICT6
Anti-corrosion: according to different media to select the corresponding measurement department material
Selection table:
|
ZDS4633
|
Selection code
|
Description
|
|
Instrument Type
|
A
|
Intelligent, imported sensor, high precision, high stability
|
|
B
|
Intelligent, high stability
|
|
Communication protocol
|
H
|
HART Communication
|
|
P
|
PROFIBUS-PA Communications
|
|
Cleaning of capsule sealing liquid/measuring part
|
1
|
Silicone oil Regular
|
|
2
|
Silicone oil Degreasing cleaning treatment
|
|
3
|
Fluorine oil Degreasing cleaning treatment
|
|
Measuring range/measuring range
|
D
|
2.5 ~ 25kPa -25 ~ 25kPa
|
|
E
|
2.5 ~ 60kPa -60 ~ 60kPa
|
|
F
|
5.3 ~ 160Kpa -160 ~ 160Kpa
|
|
G
|
16 ~ 500Kpa -500 ~ 500Kpa
|
|
T1
|
Special requirements
|
|
Isolation diaphragm
|
S
|
SUS316 stainless steel
|
|
H
|
Hastelloy C- 276
|
|
T
|
Tantalum
|
|
M
|
Monel
|
|
Flange size
|
2
|
DN 50 (2 inch)
|
|
3
|
DN 80 (3 inch)
|
|
T2
|
Special requirements
|
|
Flange standard
|
A
|
ANSI 150
|
|
B
|
ANSI 300
|
|
D
|
DIN PN 10/16
|
|
E
|
DIN PN 25/40
|
|
G
|
GB PN 10/16(GB/T9115.1-2000)
|
|
H
|
GB PN 25/40(GB/T9115.1-2000)
|
|
T3
|
Special requirements
|
|
Flange material
|
A
|
S25C Carbon steel
|
|
B
|
SUS304 Stainless steel
|
|
C
|
SU316 Stainless steel
|
|
Low side process connection
|
1
|
No process connection, chamber flange with 1/4 NPT internal thread, exhaust
The liquid discharge is on the side.
|
|
3
|
Process connector with 1/2 NPT female thread, the exhaust and liquid discharge are on the side.
|
|
T4
|
Special requirements
|
|
Explosion-proof
|
A
|
No explosion-proof
|
|
B
|
Intrinsic safety EX iall CT6.
|
|
D
|
Explosion-proof EX dII CT6.
|
|
Electrical Interface
|
1
|
1/2-14NPT internal thread, two wiring ports
|
|
2
|
M20 × 1.5 internal thread, two wiring ports
|
|
3
|
1/2 NPT electrical connector + sealing plug
|
|
4
|
1/2 NPT flameproof electrical connector + sealing plug
|
|
5
|
M20 × 1.5 electrical connector + sealing plug
|
|
6
|
M20 × 1.5 flameproof electrical connector + sealing plug
|
|
T5
|
Special requirements
|
|
Display header.
|
N
|
Without display header
|
|
D
|
LCD Display Header
|
|
T6
|
Special requirements
|
|
Selection example
|
ZDS4633 B H 1 D S 2 GB 1 A 1 D
|
|
Ordering Method
|
C D W the selection personnel can ignore it.
|