Technical parameters
Working frequency: 100MHz
Measuring range: cable type: 0-35m rod type, coaxial type: 0-6m
Repeatability: ±3mm
Resolution: 1mm
Sampling: echo sampling 54 times/s
Response speed:>0.2S (depending on the specific use)
Accuracy:<0.1%
Output current signal: 4-20mA
Communication interface: HART communication protocol
Process connection: G1-1/2,G3/4 Flange: DN50, DN80, DN100, DN150
Process pressure:-1 ~ 60bar
Power supply: 24VDC(± 10%) Ripple voltage: 1Vpp
Power consumption: max22.5mA
Environmental conditions: temperature: -40 ℃ ~ +250 ℃
Enclosure protection class: IP68
Explosion-proof grade: EXiaIICT6
Cable entry: M20 × 1.5 (cable diameter 5~9mm)
Selection table:
|
ZDW921
|
Selection code
|
Description
|
|
Grade
|
A
|
High precision, high stability
|
|
B
|
High stability
|
|
Explosion-proof grade
|
P
|
Standard type (without explosion-proof)
|
|
I
|
Intrinsic safety type (Ex ia II CT6).
|
|
C
|
Intrinsic safety type + marine license (Ex ia II CT6).
|
|
G
|
Intrinsic safety type + explosion-proof type (Ex d[ia] II CT6).
|
|
Detection component type/material
|
A
|
Cable type/Φ6mm/stainless steel 316L/PTFE
|
|
B
|
Rod type/Φ6mm/stainless steel 316L/PTFE
|
|
C
|
cabled/stainless steel 316L/ceramic
|
|
D
|
Rod/stainless steel 316L/ceramic
|
|
E
|
Double cable/Φ4mm/stainless steel 316L/PTFE
|
|
F
|
Double rod/Φ8mm/stainless steel 316L/PTFE
|
|
G
|
Coaxial type / stainless steel 316L.
|
|
T1
|
Special requirements
|
|
Electronic components
|
A
|
4 ~ 20mA two-wire system
|
|
B
|
4~20mAHART two-wire system
|
|
C
|
4 ~ 20mA/24VDC220V four-wire system
|
|
D
|
4 ~ 20mA/24VDC220V/HART four-wire system
|
|
Process Connection
|
GP
|
Thread G1/₂ A
|
|
KP
|
Thread G2A
|
|
NP
|
Thread 1/₂ NPT
|
|
T2
|
Special requirements
|
|
Seal/Process Temperature
|
A
|
Viton fluorine rubber/(-30~150)℃
|
|
B
|
Kalrez perfluorinated rubber/(-40~150)℃
|
|
T3
|
Special requirements
|
|
Enclosure/Degree of Protection
|
A
|
Aluminum/IP67
|
|
D
|
Aluminum two-chamber/IP67
|
|
G
|
Stainless Steel 316L/IP67
|
|
Cable entry
|
M
|
M20 × 1.5
|
|
N
|
/NPT
|
|
Field Display
|
A
|
Have
|
|
X
|
None
|
|
Selection example
|
ZDW921 BPAA GP BDNX
|
|
Ordering Method
|
C D W the selection personnel can ignore it
|