The remote differential pressure transmitter is a device where a capillary tube connects the differential pressure transmitter with the measured equipment. It is a type of remote sensing device installed on pipelines or containers to sense the measured pressure. This pressure is transmitted to the transmitter body through the silicone oil (or other liquids) inside the capillary tube. The pressure or differential pressure is then converted into a 4–20mA DC signal (with HART digital communication overlay) or PROFIBUS-PA communication signal output by the δ chamber and amplification circuit board within the transmitter body. When paired with a hand-held communicator that conforms to the HART protocol, they can communicate with each other for setting and monitoring.

The ZDS4833 remote differential pressure transmitter (flat diaphragm type) has various types of remote sensing configurations. Its main structure is the same as that of a differential pressure transmitter and is used for measuring liquid levels. It is widely used in industries such as petroleum, chemicals, power, food, paper-making, and municipal engineering.

Product Parameters

Technical parameters:

Measurement range: 2.5Kpa ~ 500Kpa

Span ratio: 20:1

Power supply: 10.5V ~ 45V DC (Intrinsic safety barrier power supply. ≤ 30V DC)

Output: 4mA ~ 20mA DC and HART communication; PROFIBUS-PA communication

Ambient temperature:-40 ℃ ~ 85 ℃

Medium temperature:-40 ℃ ~ 300 ℃ (filled with silicone oil)

Accuracy: ≤(0.005r +0.071)%

Temperature drift: ≤(0.1r +0.2)%(-10 ℃ ~ 60 ℃)

≤(0.1r +0.15)%/10 ℃(-40 ℃ ~-10 ℃; 60~85 ℃)

Long-term drift: ≤ 0.2 r%/5 years

Enclosure protection class: IP67

Explosion-proof grade: Ex iaIICT6 or Ex dIICT6

Anti-corrosion: according to different media to select the corresponding measurement department material

Selection table:

ZDS4833

Selection code

Description

Instrument Type

A

Intelligent, imported sensor, high precision, high stability

B

Intelligent, high stability

Communication protocol

H

HART Communication

P

PROFIBUS-PA Communications

Enclosure liquid of capsule

1

Silicone oil

Measuring range/measuring range

D

2.5 ~ 25kPa -25 ~ 25kPa

E

3 ~ 60kPa -60 ~ 60kPa

F

8 ~ 160kpa -160 ~ 160kpa

G

25 ~ 500kpa -500 ~ 500kpa

T1

Special requirements

Isolation diaphragm

S

SUS316 stainless steel

H

Hastelloy C- 276

T

Tantalum

M

Monel

Flange size

2

DN 50(2 inch)

3

DN 80(3 inch)

T2

Special requirements

Flange standard

A

ANSI 150

B

ANSI 300

D

DIN PN 10/16

E

DIN PN 25/40

G

GB PN 10/16(GB/T9115.1-2000)

H

GB PN 25/40(GB/T9115.1-2000)

K

GB PN 100 (GB/T9115.1-2000)

T3

Special requirements

Flange material

A

S25C Carbon Steel

B

SUS304 Stainless steel

C

SU316 Stainless steel

Remote sealed liquid/liquid temperature

A

General type (silicone oil) -10-250 ℃

B

General type (silicone oil) -30-180 ℃

C

High temperature type (silicone oil) 10-300 ℃

Measurement Department Cleaning

A

Regular

B

Degreasing cleaning treatment

Capillary length (m)

Customer fill options (e. g. 3m: 03)

Explosion-proof

A

No explosion-proof

B

Intrinsic safety EX ia ll CT6.

D

Explosion-proof EX dII CT6.

Electrical Interface

1

1/2-14NPT internal thread, two wiring ports

2

M20 × 1.5 internal thread, two wiring ports

3

1/2 NPT electrical connector + sealing plug

4

1/2 NPT flameproof electrical connector + sealing plug

5

M20 × 1.5 electrical connector + sealing plug

6

M20 × 1.5 flameproof electrical connector + sealing plug

T4

Special requirements

Display header

N

Without display header

D

LCD Display Header

T5

Special requirements

Mounting bracket

A

Horizontal mounting bracket (carbon steel)

B

Horizontal mounting bracket (stainless steel)

N

None

Selection example

ZDS4833 B H 1 D S 24 B A A 03 D1 DN

Ordering Method

C D W the selection personnel can ignore it.