ZDL94 Series Vortex Flow Meter
Negotiable
China
Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin
+86 18526430909
Online Contact
Favorite
Product Introduction

The Vortex Flow Meter uses advanced micro-processing technology, offering features such as strong functionality, wide flow range, simple operation and maintenance, and easy installation. It is a new type of gas flow meter, with technical indicators that meet or exceed the advanced level of similar foreign products.

The intelligent vortex flow meter integrates flow, pressure, and temperature detection functions, and is capable of performing compressibility factor compensation. This new-generation flow meter adopts advanced low-power MCN technology, is compact, easy to operate, and is an ideal instrument for gas measurement in industries such as petroleum, chemicals, power, and metallurgy.

The steam vortex flow meter employs advanced dual-probe vortex flow sensor technology. It has strong anti-interference capabilities, high accuracy, no mechanical moving parts, resistance to corrosion, compact structure, high reliability, good stability, and requires minimal maintenance.

Product Parameters

Technical parameters:

①Standard status: 20 ℃, 101.325Kpa; 15.5 ℃, 101.325Kpa; 12 ℃, 101.325Kpa or 0 ℃, 101.325Kpa

②The compensation method is optional: full compensation of temperature and pressure; only pressure compensation; only temperature compensation or no compensation of temperature and pressure

③Ambient temperature:-30 ℃ ~ +50 ℃

④Medium temperature:-20 ℃ ~ +80 ℃

⑤Relative humidity: 5% ~ 95%

⑥The atmospheric pressure: 86KPa ~ 106KPa

⑦Working power supply: internal power supply: 3V lithium battery power supply external power supply: DC24V (10V ~ 27V)

⑧Output signal (optional):

a)4 ~ 20mA two-wire or three-wire output, load 0~750 Ω, external power supply (DC12V ~ 24V) must be used in this case.

b) RS485 communication interface or RS232 communication interface is optional

c) Pulse output: The pulse output without compensation is synchronized with the input pulse. The pulse output after compensation and the current output after compensation cannot be used simultaneously.

⑨Table body material: 1Cr18Ni9Ti stainless steel

⑩Data retention time: 10 years

Selection table:

ZDL94

Model selection code

Description

Instrument Type

A

High precision, high stability

B

High stability

Sales mode

C, D, W (The selection personnel can be ignored)

Nominal diameter

1

Φ25

2

Φ32

3

Φ50

4

Φ80

5

Φ100

6

Φ150

7

Φ200

T1

SPECIAL REQUIREMENTS

Volume flow range (m³/h)

A

2 ~ 25

B

3.5 ~ 45

C

8 ~ 100

D

22 ~ 350

E

50 ~ 750

F

150 ~ 2250

G

240 ~ 3600

T2

SPECIAL REQUIREMENTS

Working pressure rating (Mpa)

1

1.6 ~ 4

T3

SPECIAL REQUIREMENTS

Accuracy Class

1

1.0

5

1.5

T4

SPECIAL REQUIREMENTS

Selection example

ZDL94-C4C15